ENVIRONMENTAL CHARACTERISTICS (Qualification Data available for review):
Parameter
Symbol
Min
Typ
Max
Unit
Operating Ambient Temperature
T
C
-10
+50
°C
Non-operating Temperature
T
STG
-40
+85
°C
Relative Humidity (non-condensing)
RH
95
%
Shock / Vibration - MIL-STD-810F
Shock Method 516.5, Vibration Method 514.5
SH / VI
PROTECTIONS:
Parameter
Specifications
Unit
Input Overdrive
+10 dBm
Max
VSWR Protection
At 3:1 – PA backs-off output power to a safe operating level – no
system shutdown, “On Air” time is maximized
-
Thermal – Graceful Degradation
Ambient 50ºC
Min
Default Data Recovery
Factory Default Calibration Recovery
COMMUNICATION INTERFACES:
Function
Utility
Connector
Ethernet
Network management of device / web interface
RJ45
USB
Mass storage / Expansion Bus
USB 1.x/2.0 compatible
RS-232 (default) RS-422 (optional)
Serial management of device / local operator access
D-Sub 9-position Male
SYSTEM I/O CONNECTOR – 14-Position
Pin #
Description
Specifications
1
FWD TP
Forward detected power (analog voltage: 0-5 Volt)
2
REV TP
Reverse detected power (analog voltage: 0-5 Volt)
3
Summary Fault
Summary Fault: Active TTL Logic Low (
≤0.7V)
(Internally Pulled-High)
4
VVA control
Gain control/Monitor: Analog Voltage Range 0-5V
Gain Control: 0V= Max. Attenuator, 5V= Min. Attenuator
5
Shutdown
Amplifier Disable: TTL Logic Low (
≤0.7V)
(Internally Pulled-High)
6
Aux P/S TP
+12.0V
DC
±2V (resettable 0.5amp fuse)
7
Main P/S TP
+44.0V
DC
±4.8V (resettable 0.5amp fuse)
8
GND
Ground
9
Open drain control
Site management utility (reserved)
10
Open drain control
Site management utility (reserved)
11
Open drain control
Site management utility (reserved)
12
Digital I/O (configurable)
Site management utility (reserved)
13
Digital I/O (configurable)
Site management utility (reserved)
14
GND
Ground