beautypg.com

Solid state broadband high power amplifier – Atec Empower-2170 User Manual

Page 2

background image

Solid State Broadband High Power Amplifier

2170 – BBS4A6AUT

1000 - 3000 MHz / 1000 Watts


ENVIRONMENTAL CHARACTERISTICS (Qualification Data available for review):

Parameter

Symbol

Min

Typ

Max

Unit

Operating Ambient Temperature

T

C

-10

+50

°C

Non-operating Temperature

T

STG

-40

+85

°C

Relative Humidity (non-condensing)

RH

95

%

Shock / Vibration - MIL-STD-810F
Shock Method 516.5, Vibration Method 514.5

SH / VI

PROTECTIONS:

Parameter

Specifications

Unit

Input Overdrive

+10 dBm

Max

VSWR Protection

At 3:1 – PA backs-off output power to a safe operating level – no

system shutdown, “On Air” time is maximized

-

Thermal – Graceful Degradation

Ambient 50ºC

Min

Default Data Recovery

Factory Default Calibration Recovery

COMMUNICATION INTERFACES:

Function

Utility

Connector

Ethernet

Network management of device / web interface

RJ45

USB

Mass storage / Expansion Bus

USB 1.x/2.0 compatible

RS-232 (default) RS-422 (optional)

Serial management of device / local operator access

D-Sub 9-position Male

SYSTEM I/O CONNECTOR – 14-Position

Pin #

Description

Specifications

1

FWD TP

Forward detected power (analog voltage: 0-5 Volt)

2

REV TP

Reverse detected power (analog voltage: 0-5 Volt)

3

Summary Fault

Summary Fault: Active TTL Logic Low (

≤0.7V)

(Internally Pulled-High)

4

VVA control

Gain control/Monitor: Analog Voltage Range 0-5V
Gain Control: 0V= Max. Attenuator, 5V= Min. Attenuator

5

Shutdown

Amplifier Disable: TTL Logic Low (

≤0.7V)

(Internally Pulled-High)

6

Aux P/S TP

+12.0V

DC

±2V (resettable 0.5amp fuse)

7

Main P/S TP

+44.0V

DC

±4.8V (resettable 0.5amp fuse)

8

GND

Ground

9

Open drain control

Site management utility (reserved)

10

Open drain control

Site management utility (reserved)

11

Open drain control

Site management utility (reserved)

12

Digital I/O (configurable)

Site management utility (reserved)

13

Digital I/O (configurable)

Site management utility (reserved)

14

GND

Ground

316 W. Florence Ave.
Inglewood, CA 90301

Ph. 1 (310) 412-8100

Fax. 1 (310) 412-9232

www.EmpowerRF.com

Stock No. 2170

NPI Rev 1.1 / 08-02-2013