beautypg.com

Ordering information, Warranty and service – Atec Agilent-11970 Series User Manual

Page 4

background image

4

Agilent model

number

Flange

Weight X

Y

Z

11970K

UG-595/U

WR-42

0.17 kg

0.36 lb

36 mm

1.4 in

51 mm

2.0 in

90 mm

3.5 in

11970A

UG-599/U

WR-28

0.14 kg

0.32 lb

36 mm

1.4 in

51 mm

2.0 in

71 mm

2.8 in

11970Q

UG-383/U

WR-22

0.14 kg

0.32 lb

36 mm

1.4 in

51 mm

2.0 in

76 mm

3.0 in

11970U

UG-383/U-M

WR-19

0.14 kg

0.32 lb

36 mm

1.4 in

51 mm

2.0 in

76 mm

3.0 in

11970V

UG-385/U

WR-15

0.14 kg

0.32 lb

36 mm 51 mm 76 mm
1.4 in

2.0 in

3.0 in

11970W

UG-387/U

WR-10

0.14 kg

0.32 lb

36 mm

1.4 in

51 mm

2.0 in

76 mm

3.0 in

11970 Series tested with Agilent PXA signal analyzer

Agilent model

number

Frequency

range

(GHz)

LO

harmonic

number

1

Maximum

conversion

loss (dB)

Nominal signal

analyzer noise (dBm)

2

1 kHz BW

Frequency

response

(dB)

Nominal gain

compression

(dBm)

11970A

26.5 to 40

6–/8–

26

–110/–108

±1.9

–5

11970Q

33 to 50

8–/10–

28

–108/–106

±1.9

–7

11970U

40 to 60

10–

28

–106

±1.9

–7

11970V

50 to 75

12–/14–

40

–96/–94

±2.1

–3

11970W

75 to 110

18–

46

–88

±3.0

–1

1. When used with 11970 Series mixer in A-, Q-, or V-band, the PXA’s LO harmonics are automatically switched between two different numbers as listed

to optimize conversion loss.

2. If the LO harmonics are switched, the noise levels for the signal analyzer/mixer combination will change, corresponding to the different LO harmonic numbers.

Ordering Information

11970K*

18 to 26.5 GHz mixer

11970A

26.5 to 40 GHz mixer

11970Q

33 to 50 GHz mixer

11970U

40 to 60 GHz mixer

11970V

50 to 75 GHz mixer

11970W

75 to 110 GHz mixer

Options:
11970X-009

11970X-C01

N9029A-E13**

Mixer connection kit containing three

1-meter SMA cables, wrench, and allen

driver. Note: X = K, A, Q, U, V or W
Improved EMC radiated susceptibility.

Note: X = K, A, Q, U, V or W
Ordering convenience for one OML INC.

LO/IF diplexer with cables and adapter

* Not compatible with N9030A PXA

** Required if the 11970 mixer is used with the Agilent PXA

Warranty and Service

Standard warranty for 11970 mixers is 12 months

Standard warranty for N9029A-E13 diplexer is 3 months,

provided by OML, Inc.