General specifi cations (continued)
Model number
83020A
83050A
83051A
*Bias voltage and current
(nominal)
15 ±1.5 Vdc at 3200 ±800 mA
12 ±1 Vdc at 900 ±110 mA
12 ±1 Vdc at 314 ±34 mA
–15 ±0.5 Vdc at 20 ±5 mA
–12 ±1 Vdc at 30 ±5 mA
–12 ±1 Vdc at 30 ±5 mA
RF connectors
3.5 mm (f)
2.4 mm (f)
2.4 mm (f)
Detector output
BNC (f)
N/A
N/A
Detector sensitivity
1 μV/μW
N/A
N/A
Detector polarity
Negative N/A
N/A
Weight: net shipping
3.9 kg (8.5 lb)
0.64 kg (1.4 lb)
0.64 kg (1.4 lb)
5.0 kg (11 lb)
1.32 kg (2.9 lb)
1.32 kg (2.9 lb)
*Do not apply positive voltage before negative voltage.
Environmental specifi cations
Temperature coeffi cient
of gain
–0.19 dB/° C
–0.09 dB/° C
–0.09 dB/° C
Operating temperature
0 to +55° C
0 to +55° C
0 to +55° C
Storage temperature
–40 to +70° C
–40 to +70° C
–40 to +70° C
Other environmental information
EMC
1
IEC 61326:1997/EN 61326:1997
CISPR 11:1997/EN 55011:1998, Group 1, Class A
Safety
IEC 348:1978/HD 401 S1:1981
CAN/CSA-C22.2 No. 231 (Series M-89)
Moisture resistance
65° C at 95% RH for 10 days per Mil-Std-883C method 1004.5
Random vibration
5.2 G (rms) to 2000 Hz per Mil-Std-883C method 2026 test condition 11A
Shock
1500 G (peak), 0.5 ms per Mil-Std-883C method 2002.3 test condition B
Altitude, non-operating
15,000 m per Mil-Std-883C method 1001 test condition C
1. This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB -001 du Canada.
Specifi cations: describe the instrument’s warranted performance over the temperature range +20° C to +30° C (unless otherwise noted).
All specifi cations apply after the instrument’s temperature has been stabilized after one hour continuous operation. Typical characteristics
are intended to provide information useful in applying the instrument by giving typical but nonwarranted performance parameters. These
are denoted as “typical” or “nominal” and apply over the temperature range +20° C to +30° C.
Caution on Electrostatic Discharge: Electrostatic discharge (ESD) can damage or destroy electronic components. It is recommended that these
amplifi ers, like other electronic components, be installed and operated at a static-free workstation or in an environment where precautions
against ESD have been implemented.