7782hc, 7782 frequency response – Atec AE-Techron_7782 User Manual
Page 2
7782and 7782HC Datasheet
Information subject to change.
3/12/12
AC Specifications
7782HC
PEAK OUTPUT
RMS OUTPUT
40mSec Pulse,
20% Duty Cycle
5 Minute,
100% Duty Cycle
5 Minute,
100% Duty Cycle
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
1
56
56
55
55
39
39
0.5
42
84
41
82
29
58
0.1
15
150
7782 DC Power Over Time Summary
Time in Minutes
Impedance
Volts
Amps
2
1
50
50
2
0.5
30
60
1.5
0.27
19
75
5
1
40
40
5
2
84
42
Continuous
2
42
21
Output Offset Current:
Less than 10 milliamperes DC
DC Drift:
7782/7782HC: ±1.5 mV
7782P/7782HC-P: ± 200 µV (from
cold to maximum
operating temperature); ±75 µV
(after 20 minutes of operation)
7782P/7782HC-P Gain Linearity
(over input signal, from 0.2 V to 5 V):
DC: 0.0125%
AC: 0.030%
Input Characteristics
Balanced with Ground:
Three terminal barrier block connector
20k ohm differential
Gain:
Voltage Mode: 20 volts/volt
Current Mode: 20 amperes/volt
Residual Noise:
Less than 1 millivolt RMS
Slew Rate:
40 volts per microsecond
Display, Control, Status
Front Panel
LED Displays indicate:
Ready, Standby, High AC Mains, High
Temperature, Signal Overload, and
Fault conditions in the output stage
Slide Switches for:
Run/Standby, LED Indicator Reset
AC Specifications
7782
PEAK OUTPUT
RMS OUTPUT
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Watts
4
120
30
120
30
85
21
85
21
1799
2
120
60
115
58
85
42
81
41
3305
1
80
80
68
68
57
57
48
48
2311
0.5
46
92
44
88
33
65
31
62
1935
-5
-4
-3
-2
-1
0
1
0
20
40
60
80
100
120
dB
Frequency in kHz
7782 Frequency Response
8 ohm
1 watt