beautypg.com

Atec AE-Techron_7782 User Manual

Atec Equipment

background image

2 5 0 7 W a r r e n S t r e e t , E l k h a r t , I N 4 6 5 1 6 U S A | 5 7 4 . 2 9 5 - 9 4 9 5 | w w w . A E T e c h r o n . c o m


7782 and 7782HC Datasheet

Information subject to change.

3/12/12

7782 and 7782HC

SPECIFICATION SHEET

The AE Techron 7782 is a 3.3 kW
power amplifier that has a DC to
50kHz small signal band-width,
150Vpk, and up to 150Apk power. The
7782 is the original member of the
7000 series, offered now as a
remanufactured product; it offers a
balance of great value, reliability and
strong performance.

The 7782 works best into loads of 2
ohms or less. A single 7782 can
provide 40mSec bursts up to 150Apk.
For greater voltage or current, units
can be combined in parallel or series
to create arrays of amplifiers capable
of pulses in excess of 500Vpk and
600Apk.

The 7782 can operate in either voltage
or current operation modes.

It is useful

for a wide variety of EMC power
susceptibility tests, including MIL STD-
461 and DO-160. The 7782 is also
typically used as a gradient amplifier in
small bore, high-gain MRI systems of
up to 150Apk per axis.

Performance

Maximum Continuous Output
Power:
3305 watts RMS

Output Offset:
7782/7782HC:
Less than 5 mV, field
adjustable to less than 1 mV

7782P/7782HC-P: Less than 200

V,

field adjustable to less than 100

V;

adjustment via 20-turn precision trim
control; DC offset adjustment range is
±10 mV with about 0.9 mV
per turn

Features

Over 3,300 watts RMS into a 2-ohm load.

40 mSec pulses of up to 150 amperes peak into a 1-ohm load.

System output of 500 volts and 200 amperes maximum are
possible with multiple, interconnected amplifiers.

Frequency bandwidth of DC to 50 kHz at rated power into 8
ohms; DC to 100 kHz at reduced power.

Rugged chassis for stand-alone or rack mounted operation. No
additional power supplies are required.

Protection circuitry protects against input overloads, improper
output connection (including shorted and improper loads), over-
temperature, over-current, and supply voltages that are too high
or low.

Optional “P” versions offer precision control of output offset, DC
drift and gain linearity.

Shipped ready to operate from 208-volt (±10%) three-phase AC
mains. Operation from 400-volt (±10%) AC mains is available
on request.

0

20

40

60

80

100

0

50

100

150

Vol

ts R

M

S

Frequency (kHz)

7782 Voltage Potential

8 ohms