1040l power amplifier, Temperature range, Ac power requirements – Atec ENI-EI-1040L User Manual
Page 2: Cooling, Weight, Dimensions
![background image](/manuals/318519/2/background.png)
1387 Brighton Henrietta Townline Rd
Rochester, NY 14623
Tel: (585) 214 0598
Fax: (585) 214 0580
www.eandiltd.com
Class of Operation
Class AB
Frequency Range
10 to 5000 KHz
Rated Power Output
400 Watts
Saturated Power Output
500 Watts
Power Gain
55 dB nominal
Gain Flatness
+/- 1 dB to 1 MHz
- 2 dB to 5 MHz
Input Power for Rated Output
1.3 mW or 1.14dBm
Input Impedance
50
Output Impedance
50
Ruggedness
Any load VSWR, any phase from open
to Short circuit without damage.
Front Panel Accuracy
+/- 3%
Drive Source Requirements
Any signal Generator, function
Generator or oscillator capable
of up to 0.7 Vpp into 50
Protection:
INPUT: unit will withstand up to +13dBm input
without damage.
MISMATCH: the unit will tolerate any mismatch
subject to thermal and current protection.
Accessories Supplied
The unit is supplied with an operations manual
and AC line cord.
Temperature Range
0
– 45
O
C
AC Power Requirements
104
– 240 VAC
9 A @ 120 V
4.5 A @ 240 V
Cooling
Forced air.
Weight
45 lbs (16 KG)
Dimensions
(H x W x D)
5.3” x 16.5” x 18.4”
134.5 mm x 420 mm x 467 mm
1040L
POWER AMPLIFIER