Ab c d g – Atec Agilent-60502B User Manual
Page 4
For more information in the U.S.A. call
1-800
-4
52
-4844
AGILENT dc ELECTRONIC LOADS
41
6060B, 60502B
6063B, 60503B
60501B
60504B
60507B
Analog programming
10 kHz (–3 dB frequency)
10 kHz (–3 dB frequency)
10 kHz (–3 dB frequency)
10 kHz (–3 dB frequency)
10 kHz (–3 dB frequency)
bandwidth
Analog programming
accuracy
Current (low range)
4.5% ±75 mA
3% ±8 mA
4.5% ±40 mA
4% ±200 mA
4.5% ±75 mA
Current (high range)
4.5% ±250 mA
3% ±20 mA
4.5% ±130 mA
4% ±400 mA
4.5% ±200 mA
Temperature coefficient 100 ppm/˚C ±6 mA/˚C
150 ppm/˚C ±1 mA/˚C
100 ppm/˚C ±3 mA/˚C
100 ppm/˚C ±12 mA/˚C
150 ppm/˚C ±6 mA/˚C
Voltage
0.8% ±200 mV
0.5% ±150 mV
0.8% ±200 mV
0.8% ±200 mV
0.8% ±375 mV
Temperature coefficient 100 ppm/˚C ±1 mV/˚C
120 ppm/˚C ±10 mV/˚C
100 ppm/˚C ±1 mV/˚C
100 ppm/˚C ±1 mV/˚C
120 ppm/˚C ±12.5 mV/˚C
Analog programming
0 to 10 V
0 to 10 V
0 to 10 V
0 to 10 V
0 to 10 V
voltage
Readback specifications 17 mA (via HP-IB)
2.7 mA (via HP-IB)
9 mA (via HP-IB)
34 mA (via HP-IB)
17 mA (via HP-IB)
Current readback resolution 20 mA (front panel)
10 mA (front panel)
10 mA (front panel)
100 mA (front panel)
20 mA (front panel)
Temperature coefficient 50 ppm/˚C ±5 mA/˚C
100 ppm/˚C ±1 mA/˚C
65 ppm/˚C ±3 mA/˚C
100 ppm/˚C ±8 mA/˚C
100 ppm/˚C ±5 mA/˚C
Voltage readback resolution 17 mV (via HP-IB)
67 mV (via HP-IB)
17 mV (via HP-IB)
20 mV (via HP-IB)
40 mV (via HP-IB)
20 mV (front panel)
100 mV (front panel)
20 mV (front panel)
20 mV (front panel)
100 mV (front panel)
Temperature coefficient 50 ppm/˚C ±1.2 mV/˚C
100 ppm/˚C ±8 mV/˚C
50 ppm/˚C ±1.2 mV/˚C
100 ppm/˚C ±2 mV/˚C
100 ppm/˚C ±5 mV/˚C
Analog monitor accuracy
Current monitor (0 to 10 V out)
4% ±85 mA
3% ±10 mA
4% ±40 mA
4% ±170 mA
3% ±85 mA
Temperature coefficient 50 ppm/˚C ±6 mA/˚C
100 ppm/˚C ±1 mA/˚C
60 ppm/˚C ±3 mA/˚C
100 ppm/˚C ±10 mA/˚C
100 ppm/˚C ±6 mA/˚C
Voltage monitor (0 to 10 V out)
0.25% ±40 mV
0.4% ±240 mV
0.25% ±40 mV
0.4% ±60 mV
0.4% ±120 mV
Temperature coefficient 50 ppm/˚C ±0.2 mV/˚C
70 ppm/˚C ±1.2 mV/˚C
50 ppm/˚C ±0.2 mV/˚C
100 ppm/˚C ±2 mV/˚C
100 ppm/˚C ±5 mV/˚C
Remote sensing
5-Vdc maximum between sense and load input
Minimum operating voltage 2 volts (1.2 V typical)
2 volts (1.2 V typical)
2 volts (1.2 V typical)
2 volts (1.4 V typical)
2 volts (1.4 V typical)
(at full rated current)
Programmable short
0.033
Ω
(0.020
Ω
typical)
0.20
Ω
(0.10
Ω
typical)
0.066
Ω
(0.040
Ω
typical)
0.017
Ω
(0.012
Ω
typical)
0.033
Ω
(0.025
Ω
typical)
Programmable open
20 k
Ω
80 k
Ω
20 k
Ω
20 k
Ω
20 k
Ω
(typical)
Drift (over 8-hour interval)
Current
0.03% ±10 mA
0.03% ±15 mA
0.03% ±5 mA
0.03% ±20 mA
0.03% ±10 mA
Voltage
0.01% ±10 mV
0.01% ±20 mV
0.01% ±10 mV
0.01% ±10 mV
0.01% ±25 mV
dc isolation voltage
±240 Vdc, between any input and chassis ground
Digital inputs
V
IL
= 0.9 V max at I
IL
= –1 mA / V
IH
= 3.15 V min (pull-up resistor on input)
Digital outputs
V
OL
= 0.72 V max at I
OL
= 1 mA / V
OH
= 4.4 V min at I
OH
= –20 µA
Net weight
6060B: 6.12 kg (13.5 lb)
6063B: 6.12 kg (13.5 lb)
3.2 kg (7 lb)
5.4 kg (13 lb)
5.4 kg (13 lb)
(approx.)
60502B: 3.2 kg (7 lb)
60503B: 3.2 kg (7 lb)
Shipping weight
6060B: 8.16 kg (18 lb)
6063B: 8.16 kg (18 lb)
4.5 kg (10 lb)
7.3 kg (16 lb)
7.3 kg (16 lb)
60502B: 4.5 kg (10 lb)
60503B: 4.5 kg (10 lb)
Supplemental Characteristics (cont’d)
Net Weight:
6050A: 9.5 kg (21 lb); 6051A: 5.5 kg (12 lb)
Shipping Weight:
6050A: 13.6 kg (30 lb); 6051A: 7.5 kg (17 lb)
Size:
6050A:
425.5 mm W x 177 mm H x 624.7 mm D
(16.75 in x 7 in x 24.6 in )
6051A:
213 mm W x 177 mm H x 624.7 mm D
(8.4 in x 7 in x 24.6 in )
6060B, 6063B:
425.5 mm W x 88.1 mm H x 396 mm D
(16.75 in x 3.5 in x 13.7 in ).
See pages 49 and 50 for dimension drawings
Option Descriptions
Opt 020
Front-Panel Inputs (for 6060B and 6063B only)
Opt 100
87 to 106 Vac, 47 to 66 Hz input (for Japan only)
Opt 220
191 to 233 Vac, 47 to 66 Hz input
Opt 240
209 to 250 Vac, 47 to 66 Hz input
* Opt 800
Rack-mount Kit for two units (for 6051A) mounted
side-by-side (p/n 5061-9694 and 5063-9215)
* Opt 908
Rack-mount Kit (p/n 5063-9215 with 6050A,
p/n 5063-9245 with 6051A, and p/n 5063-9212
with 6060B and 6063B)
* Opt 909
Rack-mount Kit with Handles (p/n 5063-9222
when mounting 6050A and p/n 5063-9219 when
mounting 6060B and 6063B)
Opt 910
Extra manual set, including one each of the operating
manual, programming reference manual, and service manual.
The programming manual is available with the mainframe, and
therefore not with individual modules.
* Options 908 and 909 for the 6050A, and Options 800 and 908 for the
6051A, require either the slide kit (p/n 1494-0059) or support rails
(p/n E3663AC) to support the weight of the load mainframe.
GPIB Interface Capabilities
The following GPIB functions are implemented: SH1, AH1,
L4, SR1, DC1, DT1, and RL1
Regulatory Compliance:
Listed to UL 1244; certified to CSA556B;
conforms to IEC 61010-1. See page 69 for more information.
Notes: 1. Operating temperature range is 0˚ to 55˚ C. All specifications apply for 25˚ C ±5˚ C, except as noted.
2. Maximum continuous power available is derated linearly from 40˚ C to 75% of maximum at 55˚ C.
3. DC current accuracy specifications apply 30 seconds after input is applied.
A
B
C
D
G
dc