beautypg.com

Specifi cations, continued – Atec Agilent-6060B User Manual

Page 4

background image

4

Specifi cations, continued

Supplemental characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)

6060B

6063B

Analog monitor accuracy

Current monitor (0 to 10 V

out

)

4% ± 85 mA

3% ± 10 mA

Temperature coeffi cient

50 ppm/°C ± 6 mA/°C

100 ppm/°C ± 1 mA/°C

Voltage monitor (0 to 10 V

out

)

0.25% ± 40 mV

0.4% ± 240 mV

Temperature coeffi cient

50 ppm/°C ± 0.2 mV/°C

70 ppm/°C ± 1.2 mV/°C

Remote sensing

5-VDC maximum between sense and
load input

5-VDC maximum between sense and
load input

Minimum operating voltage
(at full rated current)

2 V (1.2 V typical)

2 V (1.2 V typical)

Programmable short

0.033 Ω (0.020 Ω typical)

0.20 Ω (0.10 Ω typical)

Programmable open (typical)

20 kΩ

80 kΩ

Drift (over 8-hour interval)

Current

0.03% ± 10 mA

0.03% ± 15 mA

Voltage

0.01% ± 10 mV

0.01% ± 20 mV

DC isolation voltage

± 240 VDC, between any input and
chassis ground

± 240 VDC, between any input and
chassis ground

Digital inputs

V

IL

= 0.9 V

max

at I

IL

=

–1 mA / V

IH

= 3.15 V

min

(pull-up resistor on input)

V

IL

= 0.9 V

max

at I

IL

=

–1 mA / V

IH

= 3.15 V

min

(pull-up resistor on input)

Digital outputs

V

OL

= 0.72 V

max

at I

OL

=

1 mA / V

OH

= 4.4 V

min

at I

OH

= –20 μA

V

OL

= 0.72 V

max

at I

OL

=

1 mA / V

OH

= 4.4 V

min

at I

OH

= –20 μA

Notes:
1. Operating temperature range is 0° to 55 °C. All specifi cations apply for 25 °C ± 5 °C, except as noted.
2. Maximum continuous power available is derated linearly from 40 °C to 75% of maximum at 55 °C.
3. DC current accuracy specifi cations apply 30 seconds after input is applied.