Model k571, Resistive portable load bank, Specifications – Atec Avtron-K571 User Manual
Page 2: Outline drawing
22.84
[580.00]
52.66
[1338.00]
62.41
[1585.00]
27.97
[710.40]
SCREENED AIR INTAKE THIS
SIDE AND OPPOSITE SIDE
SCREENED
AIR OUTLET
HINGED
ACCESS
PANEL
RIGID CASTERS
SWIVEL CASTERS
CONTROL
PANEL
5.50
[139.70]
HANDLE
9.75
[247.60]
5.31
[134.80]
SPECIFICATIONS:
RELIABILITY: The rugged load resistor assemblies in
the K571 are cooled by a reliable heavy duty industrial
blower. Avtron’s special air switch protects load resis-
tor elements against loss of cooling air. Full rated
contactors are used for switching all load steps.
INDICATOR LIGHTS: BLOWER ON and AIR FAILURE.
SWITCHES: ON-OFF load control for each load step.
MASTER LOAD ON-OFF control for total load (all
selected steps).
METERS (Optional): Digital volt and ammeter.
COOLING: Self-contained 0.5 HP blower, 120 V, single phase, 60 Hz.
CONTROL POWER: 120 volt, single phase, 60 Hz.
MOBILITY: 4 rubber casters: 2 rigid and 2 swivel with foot operated locks.
ACCESSORIES: Optional canvas protective cover and multi-conductor flexible load cables available.
WEIGHT: Approximately 295 lbs. [133.8 kg]
Model K571
Resistive Portable Load Bank
6255 Halle Drive • Cleveland, Ohio, U.S.A. 44125-4615 • 216.573.7600 • FAX 216.573.5953
www.avtronloadbank.com • [email protected]
Bulletin 271 • Rev. D
OUTLINE DRAWING:
K571 LOAD CAPACITY RATINGS:
Other designs available upon request. Consult Factory.
Volts DC
Amps
Load Steps in Amps
52
900
5, 10, 10, 25, 50, 100, 100, 200, 400
1000
50, 50, 100, 100, 100, 200, 200, 200
28
1000
5, 10, 10, 25, 50, 100, 200, 200, 400
All dimensions are in inches [millimeters]. Specifications subject to change without notice.
Quality System Certified to ISO 9001