beautypg.com

Ordering information, Panel description – Atec Chroma-63600 Series User Manual

Page 8

background image

1. LCD Display:

Used for setting and measurements

2. MODE key:

Used to select the operating mode : CC, CR, CV, CP or CZ

3. DYNA key:

To select dynamic test mode

4. EDIT key:

Used for setting and editing

5. SHORT key:

Used to apply a short circuit across the input

6. ADVA key:

Used to select the other testing functions

7. Enter key:

Used for confirming data entry

8. Voltage sense terminal
9. A/B key:

Used to select static A or B load (63630, 63640)

L/R key:

Used to select left or right channel of input load (63610)

10. DATA key:

Used to select the other parameters

11. RANGE key:

Used to select HIGH, MIDDLE or LOW loading range

12. Rotary knob:

Used to adjust loading and parameter setting

13. Cursor key:

Used for setting and editing

14. LOAD key:

Used to enable or disable the load input

15. Module lock:

Used to remove the module

16. Load terminal
17. Power switch

18. LED display:

Used to display the memory address

19. Up / Down key:

Used to select the next or previous memory address

20. SPEC key:

Used to setup High/Low limits for GO/NG test

21. LOCK key:

Used to lock the setting data

22. SAVE key:

Used to save the front panel input status into memory

23. RECALL key:

Used to recall the front panel input status from memory

24. LOCAL key:

Used to recover local control

25. Shortcut key:

Used to save loading profile for all channels

26. Voltage & Current monitor output:

Analog output to proportional to

the voltage and current waveform

27. V EXT:

Input for

external wave in control

28. System I/O:

Used for system input/output control signals

29. Ethernet connector
30. System Bus:

Used for master/slave control system data communication

31. USB connector
32. GPIB connector
33. AC input fuse
34. AC Input connector

OrdErINg INFOrmATION

63600-1 : 63600 Mainframe for Single Modules
63600-2 : 63600 Mainframe for 2 Modules
63600-5 : 63600 Mainframe for 5 Modules
63610-80-20 : DC Load Module, 80V/20A/100Wx2
63630-80-60 : DC Load Module, 80V/60A/300W
63630-600-15 : DC Load Module, 600V/15A/300W
63640-80-80 : DC Load Module, 80V/80A/400W

A636000 : GPIB Interface for 63600-2/63600-5 Mainframe
A636001 : Ethernet Interface for 63600-2/63600-5 Mainframe
A636003 : External Signal Board (Test Pin) for 63600-2/63600-5 Mainframe
A636005 : External Signal Board (BNC) for 63600-2/63600-5 Mainframe
A636007 : Rack Mounting Kit for 63600-2 mainframe
A636008 : Rack Mounting Kit for 63600-5 mainframe (for Europe only)
A632006 : NI USB-6211 Bus-Powered Multifunction DAQ

PANEl dESCrIPTION

1

2

9

10

3
4
5

6
7

11

12

13
14

8

16

15

17

18 19 20 21 22 23 24 25

26 27 28

29

30

31

32

33

34