Measurement applications

Time-domain capability (Option 010)

For viewing reflection and transmission responses in time or

distance domain.

Frequency offset (Option 080)

This option enables the PNA Series microwave network analyzers

to set the source frequency independently from where the

receivers are tuned. This ability is important for two general

classes of devices: mixers (and converters) and amplifiers.

Option 080 provides a very basic user interface.

Reference receiver switch (Option 081)

Option 081 adds a solid-state internal RF transfer switch in the

R1 reference-receiver path (see PNA Series Microwave Data

Sheet literature number 5989-7605EN for a block diagram). The

switch allows the instrument to easily switch between standard

S-parameter (non-frequency-offset) measurements and frequency

offset measurements such as relative phase or absolute group

delay that require an external reference mixer. The user can set

the switch manually or remotely, but it is best used with the

frequency-converter application (Option 083), where it is controlled

automatically during the vector-mixer calibration procedure

and subsequent measurements.

Scalar-calibrated converter measurements (Option 082)

With a simple setup and calibration, this application provides

the highest accuracy for conversion-loss (or gain) measurements

by combining one-port and power-meter calibrations to remove

mismatch errors. Option 080 required.

Vector- and scalar-calibrated converter measurements

(Option 083)

This converter measurement adds an intuitive and easy-to-use

user interface, advanced calibration choices that provide

exceptional amplitude and phase accuracy, and control of

external signal sources for use as local oscillators. Mixer

calibration techniques include scalar-mixer calibration and

vector-mixer calibration (requires Option 081). Finally, the

frequency-converter application supports all of Agilent’s major

signal source families.

Embedded LO Measurements (Option 084)

This option tunes the PNA receivers to the output frequency of

the converter under test, without the need for access to internal

LOs or a common reference signal. For converters with embed-

ded LOs, this option enables measurements of match-corrected

conversion loss/gain (requires Option 082 or 083), and absolute

group delay (requires Option 083).

PNA Series Network Analyzer

The microwave PNA Series instruments are integrated vector

network analyzers equipped with a built-in S-parameter test set,

synthesized source, a hard disk drive, USB interfaces, and an

8.4” LCD color touch screen display. The E8362C has 3.5 mm

male 50-ohm test ports. The E8363C/64C have 2.4 mm male

50-ohm test ports. The E8361C has 1.85 mm male 50-ohm test

ports. Included with each instrument is a mouse, keyboard (U.S.)

and a 1-year return-to-Agilent service warranty.

Test set and power configuration options

Configurable test set (Option 014)

Provides six front panel access loops. Three access loops are

for port one and three for port two. The loops provide access

to the signal path between (a) the source output and the

reference receiver, (b) the source output and directional coupler

thru arm and (c) the coupled arm of the directional coupler and

the port receiver. This option provides the capability to improve

instrument sensitivity for measuring low-level signals, to

reverse the directional coupler to achieve even more dynamic

range or to add components and other peripheral instruments

for a variety of measurement applications. (see PNA Series

Microwave Data Sheet literature number 5989-7605EN for a

basic block diagram)

Extended power range and bias-tees (Option UNL)

Adds two 60 dB step attenuators and two bias-tees to the

E8362/3/4C. Adds two 50 dB step attenuators and two bias-tees

to the E8361C. A step attenuator and bias-tee set is inserted

between the source and test port one and another set

between the source and test port two. (see PNA Series

Microwave Data Sheet literature number 5989-7605EN for a

basic block diagram)

Add receiver attenuators (Option 016)

An attenuator is added between each test port and its

corresponding receiver. Two 35 dB step attenuators are added

to the E8362/3/4C. Two 50 dB step attenuators are added to

the E8361C (see PNA Series Microwave Data Sheet literature

number 5989-7605EN for a basic block diagram).

High-power test set (Model E836xCH85)

This configuration combines options that are often necessary

for high power measurements (UNL

1

, 014, 016, 080, 081).

The only difference between ordering Option H85 versus a

combination of the options listed above is the source

attenuator option UNL. Standard UNL includes two source

attenuators and two bias-tees. Option H85 includes the two

source attenuators, but not the bias-tees, as the bias-tees are

the power-limiting factor in the network analyzer test set. The

maximum power at the test port is +43 dBm (< 20 GHz), and

+40 dBm (> 20 GHz).
Option 080, frequency-offset mode, is included in Option H85

because it manages the phase-locking internally (instead of

depending on the R1 receiver). So if you need to use external

components in the path of the R1 receiver, it makes the

measurements simpler and more robust.