beautypg.com

Pna series network analyzer, Option configurations – Atec Agilent-E8362C User Manual

Page 3

background image

PNA Series Network Analyzer

Option configurations

To add options to a product, order the corresponding item number.

Description

For E8362C

For E8363C

For E8364C

For E8361C

Additional

information

Test set

Option 014 Configurable test set

E8362C-014

E8363C-014

E8364C-014

E8361C-014

Power configuration

Option UNL Extended power range

E8362C-UNL

E8363C-UNL

E8364C-UNL E8361C-UNL Only E8361C requires 014

and bias-tees

Option 016 Add receiver attenuators

E8362C-016

E8363C-016

E8364C-016

E8361C-016 Requires UNL (only E8361C also

requires 014)

Option H85

1

High-power configuration

E8362CH85

E8363CH85

E8364CH85

Includes 014, 016, UNL

2

, 080, 081

Measurement applications

Option 010

Time-domain capability

E8362C-010

E8363C-010

E8364C-010

E8361C-010

Option 080 Frequency offset

E8362C-080

E8363C-080

E8364C-080

E8361C-080 Requires 014 (E8361C only, 081 required

if UNL is also purchased)

Option 081 Reference receiver switch

E8362C-081

E8363C-081

E8364C-081

E8361C-081 Requires 014, 080 (only E8361C also

requires UNL)

Option 082

Scalar-calibrated

E8362C-082 E8363C-082 E8364C-082 E8361C-082 Requires 014, 080

converter measurements

Option 083 Vector- and scalar-calibrated E8362C-083

E8363C-083

E8364C-083

E8361C-083 Requires 014, 080, 081(only E8361C

converter measurements

also requires UNL)

Option 084

3

Embedded LO measurements E8362C-084

E8363C-084

E8364C-084

E8361C-084

Requires 082 or 083

Option 550

4

4-port measurement application E8362C-550 E8363C-550 E8364C-550 E8361C-550 Requires 014

Option 551

4

N-port capabilities

E8362C-551 E8363C-551 E8364C-551 E8361C-551 Requires 014

Pulse, antenna, mm-wave

Option H08

Pulsed-RF measurement

E8362C-H08

E8363C-H08

E8364C-H08

E8361C-H08

Requires 014, 080 (Option H11

capability

recommended)

Option H11

IF access (for antenna,

E8362C-H11

E8363C-H11

E8364C-H11

E8361C-H11

Requires 014, UNL, 080, and 081

pulsed-RF and mm-wave

measurements)

Accessories

Option 1CM Rack mount kit for use

E8362C-1CM

E8363C-1CM

E8364C-1CM E8361C-1CM

without handles

Option 1CP Rack mount kit for use

E8362C-1CP

E8363C-1CP

E8364C-1CP

E8361C-1CP

with handles

Calibration documentation

Option 1A7 ISO 17025 compliant

E8362C-1A7

E8363C-1A7

E8364C-1A7

E8361C-1A7

calibration

Option UK6 Commercial calibration

E8362C-UK6

E8363C-UK6

E8364C-UK6

E8361C-UK6

certificate with test data

Option A6J ANSI Z540 compliant

E8362C-A6J

E8363C-A6J

E8364C-A6J

E8361C-A6J

calibration

Calibration software for self-maintainers

Option 897

5

Perpetual license of built-in

E8362C-897 E8363C-897 E8364C-897 E8361C-897

performance test software for Agilent exclusive calibration

Option 898

5

Perpetual license of built-in

E8362C-898 E8363C-898 E8364C-898 E8361C-898

performance test software for standards compliant calibration

1. Option H85 is ordered as a separate model, as indicated.

2. UNL up to 67 GHz does not include bias-tees. Only includes source attenuators.

3. Requires firmware A.07.05 and above, plus 1.1 GHz CPU board.

4. Option 550 is a subset of 551; therefore they cannot be ordered together. When ordering a test set, select an option to specify the appropriate

interconnect jumper cable set between the analyzer and the test set.

5. Additional hardware required. Please refer to the analyzer’s Service Guide for required service test equipment.

E8362C 10 MHz to 20 GHz

E8363C 10 MHz to 40 GHz

E8364C 10 MHz to 50 GHz

E8361C 10 MHz to 67 GHz

3