w w w.aeroflex.com
Bandwidth / Optional CF / DF (Q)
dB / Octave, dB / Decade Readout
Delta Marker On / Off
-1 dB gain compression
Fault Location
Find Max / Track Max
Next PK Right / Left
Set PK Level
Delta marker On / Off
General
Marker Table
Assign Active MKR / Position Active MKR
Set-up Markers (i.e. On / Off, Position)
Large Readout
All Off
Marker Resolution
Frequency: 6 digits or 1 Hz, user selectable
Power: 0.01 dB
Voltage: 1 nV
Measurement Manipulation
Display live measurement.
Display trace memory.
Display live measurement relative to trace memory.
Measurement hold may be applied for each trace.
Any input or ratio of inputs may be assigned to any one or more than
one trace(s). A trace may display absolute power, power relative to a
path calibration or power minus a trace memory.
Input Offsets
An offset in the range -99.99 dB to +99.99 dB in 0.01 dB steps may
be applied per detector input.
Weight - Variant and Option Dependent
16 kg (35 Ibs)
Size (Not including front handles)
230 mm H x 430 mm W x 570 mm D
9 in H x 17 in W x 22 in D
Power Supply
100-240 V~ (Limit 90-264 V~)
50-60 Hz (Limit 45-66 Hz)
108-118 V~ (Limit 90-132 V~)
50-400Hz (Limit 45-440 Hz)
200 W maximum
Rated Range of Use
Temperature
0 to 50°C
6825A and 6825AR only +5°C to 45°C only
Humidity
Up to 93% RH at 40°C
Conditions of Storage and Transportation
Temperature
-40 to +71°C
Humidity
Up to 93% RH at 40°C
Altitude
Up to 4570 m (15000 ft)
ELECTROMAGNETIC COMPATIBILITY
Conforms to the protection requirements of EEC Council directive
2004/108/EC.
Conforms to the limits specified in the following standards:
IEC/EN61326-1 : 2006
RF Emission Class A, Immunity table 3.
The radiated RF emission from this equipment is below Class A (refer-
ence CISPR 11). Class A equipment is intended for use in industrial
environments. There may be potential difficulties in ensuring electro-
magnetic compatibility in other environments due to radiated distur-
bances.
When using a 6230L detector, the noise floor may increase if exposed
to a conducted RF disturbance level of >1.5V.
SAFETY
Conforms with the requirements of EC Council Directive 2006/95/EC
(as amended) and the product safety standard IEC/EN 61010-1 :
2001 + C1 : 2002 + C2 : 2003 for class 1 portable equipment, for
use in a Pollution Degree 2 environment. The instrument is designed to
operate from an Installation Category 2 supply.