beautypg.com

Ordering information, Accessories, Specifications and characteristics – Atec Agilent-1156A-1157A-1158A User Manual

Page 3: Environmental conditions, Related literature

background image

3

Ordering Information

1. With the purchase of a new
54800-series Infiniium oscilloscope:

•Option #012 (54810A, 54815A

54820A, 54825A, 54835A)
for 1156A

•Option #013 (54845A) for 1157A
•Option #014 (54846A) for 1158A

2. For existing 54800-Series Infiniium
oscilloscope customers order the
1156A**, 1157A**, or 1158A**

Each probe includes:

•Foam Case

•12 Resistive signal pins (orange) (E2640A)
• 2 Solderable-tip 5 cm resistive signal leads

(E2638A)

• 2 Socket-end 5 cm resistive signal leads

(01156-82105)

• 2 Socket-end 10 cm resistive signal leads

(01156-82108)

• 4 Micro clips (E2639A)*
• 12 Ground blade assemblies (E2641A)
• 12 Solderable SMT ground pins

(1253-5054)

• 12 Solderable through-hole ground pins

(1252-7150)

• 12 Offset ground pins (01156-27606)
• 2 Solderable-tip 5 cm ground leads

(E2638A)

• 2 Socket-end 5 cm ground leads

(01156-82103)

• 2 Socket-end 5 cm, 90° pin ground leads

(01156-82104)

• 1 User and Service Guide
• One-year warranty

* The 1156A only comes with 2 micro clips.

To order additional quantities, see
Accessories.

Accessories

E2637A Precision

Measurement

kit (includes 2 solderable
ground sockets with
8 green resistive
signal pins)

E2638A

Solderable - tip 5 cm
resistive signal leads (10)
with ground leads (3)

E2639A

Micro clips, Qty. 4

E2640A

Resistive signal pins,
(orange) Qty. 8

E2641A

Ground blade assembly,
Qty. 8

E2654A

EZ-Probe® Positioner

** The Infiniium 54800-Series scope
requires version A.04.30 or greater of
the application software to work with
the 1156A/7A/8A probes. An LS-120
drive is required for this upgrade.

To receive your free Infiniium
software update, go to our Infiniium
web site:

www.agilent.com/find/Infiniium1

Probe Recommendation Table

Be sure your probe has enough bandwidth to utilize the full performance your scope offers. Use the
selection table below for recommended configurations.

Infiniium 54800-Series oscilloscope

Probe

System Bandwidth

54835A (1.0 GHz)

1156A (1.5 GHz)

1.0 GHz

54845A (1.5 GHz)

1157A (2.5 GHz)

1.5 GHz

54846A (2.25 GHz)

1158A (4.0 GHz)

2.25 GHz

Specifications and Characteristics

Bandwidth

1

(–3dB)

1156A

>1.5 GHz

1157A

>2.5 GHz

1158A

>4 GHz

System Bandwidth

1 GHz

1156A with 54835A

1.5 GHz

1157A with 54845A

2.25 GHz

1158A with 54846A

Rise and Fall time (10% to 90%)

1156A

<233 ps

1157A

<140 ps

1158A

<88 ps

calculated from tr = 0.35/bandwidth
Input Capacitance 0.8 pF
Input Resistance

1

100 k

1%

Flatness , Swept Response

0.2 dB, 100 kHz to 100 MHz
0.4 dB, 100 MHz to 2.5 GHz
2.0 dB, 2.5 GHz to 4.0 GHz

Flatness, Step Response

15% overshoot, 35 ps input edge
10% overshoot, 75 ps input edge
2%, 1 ns after edge

Dynamic Range

2

>5.0 V peak-to-peak

dc Attenuation

1

10:1 ±3% before calibration

4

10:1 ±1% after calibration

4

Zero offset error referred to input

1

<30 mV before calibration
<5 mV after calibration

Offset Range

1

±15.0 V

Offset Accuracy

1

<3% of setting before
calibration

4

1% of setting after
calibration

4

Noise referred to input

3.0 mVrms

Propagation Delay

5.5 ns

Maximum Input Voltage

40 V peak, CAT I

3

ESD Tolerance

>5 kV from 100pF,
300

HBM

Temperature Drift

Offset: <1.0 mV/°C
Attenuation (Gain):
0.1 %/°C

Environmental Conditions

Temperature

Operating

0 °C to +55 °C

Non-operating

–40 °C to +70 °C

Humidity

Operating

Up to 95% relative
humidity
(non-condensing)
at +40 °C

Non-operating

Up to 90% relative
humidity at +65 °C

Power Requirements from
AutoProbe Interface

+12 Vdc @ 3 mA typical
+ 5 Vdc @ 35 mA typical
–5 Vdc @ 37 mA typical

Weight

Approximately 0.69 kg

1

Denotes warranted specifications, all others are typical

2

For waveforms with edges >3 ns, the dynamic range is 12.0 Vpeak-to-peak

3

Installation category (over voltage category) I: Signal level, special equipment, or parts of equipment, telecommunication,

electronic, etc., with smaller transient overvoltage than installation category (overvoltage category) II.

4

Probe calibrated to scope channel (under Probes Setup menu)

Related literature

Infiniium 54800 Series Oscilloscope
Probes and Accessories
Data Sheet

5968-7141EUS/EN

Infiniium 54800 Series Oscilloscopes
Product Overview 5980-2397EUS/EN

Optimizing Oscilloscope
Measurement Accuracy on High-
Performance Systems with Agilent
Active Probes
Application Note 1385
5988-5021EN