Combination wave / surge generator – Atec EM-Test-UCS500N5V User Manual
Page 2
DATA SHEET > UCS 500N5V > 20130322
TECHNICAL DETAILS
COMBINATION WAVE / SURGE
GENERATOR
UCS 500N5V
As per EN/IEC 61000-4-5 and
EN 61000-6-1, -6-2
Voltage (o.c.)
160V - 5,000V ± 10%
Pulse front time
1.2us ± 30%
Time to half value
50us ± 20%
Current (s.c.)
Max. 2,500A ± 10%
Pulse front time
8us ± 20%
Time to half value
20us ± 20%
Polarity
Positive/negative/alternating
Event counter
1 - 30,000 or endless, selectable
TRIGGER CIRCUIT
Release of pulses
Automatic, manual, external
Synchronization
0° - 360°, resolution 1°
Repetition rate
max. 1Hz (1s - 999s)
OUTPUTS
Direct
Via HV connectors for external
coupling networks (Zi = 2ohm with
optional adapter IMN 2)
Coupling mode
Line to line
Line(s) to ground
DUT supply
AC: 300V/16A; 50/60Hz
DC: 300V/16A
CRO trigger
5V trigger signal for oscilloscope
MEASUREMENTS
CRO Û-monitor
10Vp at 5,000V
CRO Î-monitor
10Vp at 2,500A
Peak voltage
5,000V in the LCD display
Peak current
2,500A in the LCD display
COMBINATION WAVE / SURGE
GENERATOR
TEST ROUTINES
Quick Start
One-line adjustable parameters,
easy-to-use
Standard Test
routines
As per IEC 61000-4-5, Levels 1 - 4
As per EN 61000-6-1, -6-2
Manual Standard Test routine
User Test routines
Change polarity after n pulses
Change coupling after n pulses
Change voltage after n pulses
Change phase angle after n pulses
Pulsed Magnetic
Field
as per IEC 61000-4-9
Test levels 100, 300 and 1,000A/m
Test level steplessly adjustable
under Quick Start
www.emtest.com
© EM TEST > PAGE 2/4