General data, Options – Atec EM-Test-UCS-500N5E User Manual
Page 3
DATA SHEET > UCS 500N5E > 20130322
TECHNICAL DETAILS
GENERAL DATA
INTERFACES
Serial interface
USB
Parallel interface
IEEE 488, addresses 1 - 30
Analog output
0 - 10VDC to control an external
transformer
CN interface
15pin SubD connector to control an
external coupling network
Fail inputs
DUT monitoring via Fail1 and Fail2
input (one each)
DIMENSIONS
Dimensions
19", 3HU
Weight
approx. 14kg
MAINS
Supply voltage
115V/230VAC +10%/-15%
Power
approx. 75W
Frequency
50/60Hz
Fuses
2 x T 2AT (230V) or 2 x T 4AT (115V)
ACCESSORIES INCLUDED
Mains supply
Plug depends on the country of use
DUT supply
Plug depends on the country of use
DUT adapter
Socket depends on the country of
use
Operation manual,
Calibration certificate,
iec.control remote control software
OPTIONS
OPTIONAL ACCESSORIES
HFK
Capacitive coupling clamp as per
IEC 61000-4-4
KW50
100:1 divider, 50ohm
KW1000
500:1 divider, 1,000ohm
CA EFT kit
Kit for burst pulse verification
consisting of KW50, KW1000 and
adapter for DUT port in a plastic case
for storage
A6dB
6dB attenuator, 50ohm
ITP
Immunity test probes (electrical field
generation)
ITP/H
Immunity test probe (magnetic field
generation)
iec.control 1
Remote control and documentation
software, including standard test
routines and reporting capabilities.
OPTIONAL EQUIPMENT
CNI 503Ax
3-phase coupling/decoupling
networks as per IEC 61000-4-4 and
-4-5 up to 100A per phase
CNE 503x
Coupling/decoupling networks for
special EFT/Burst test applications,
e.g. for energy meters, as per
IEC 60255-22-5
www.emtest.com
© EM TEST > PAGE 3/4