Atec EM-Test-EFT-500N5 Series User Manual
Page 2
![background image](/manuals/318288/2/background.png)
DATA SHEET > EFT 500N5-series > 20130321
TECHNICAL DETAILS
EFT 500N5 MODELS
EFT 500N5.1
With 3-phase coupler, 3x 440V/32A
EFT 500N5.2
With 3-phase coupler, 3x 440V/50A
EFT 500N5.5
With 1-phase coupler, 250V/32A
EFT 500N5.8
With 3-phase coupler, 3x 690V/32A
Other couplers on request
TEST LEVEL
Voltage range
200V - 4,800V
Into 50ohm
100V - 2,400V
Pulse shape
Into 50ohm load
Rise time tr
5ns ± 30%
Pulse width td
50ns ± 30%
Pulse shape
Into 1,000ohm load
Rise time tr
5ns ± 30%
Pulse width td
35ns to 150ns
Source impedance
50 Ohm ± 20%
Polarity
Positive/negative
TRIGGER
Release of Burst
Automatic, manual, external
Burst duration
Td = 0.1ms - 999.9ms
Burst repetition
rate
Tr = 10ms - 9,999ms
Spike frequency
f = 0.1kHz - 1,000kHz
Test duration
T = 0:01 min - 99:59 min
T > 99:59 min - endless
OUTPUT
Direct
Via HV coax connector
Coupler
L, N and PE, all combinations
DUT supply AC
single phase: 250V/32A, 50/60Hz
three-phase: 3x440V/32A or 50A,
50/60Hz
DUT supply DC
250V/10A
DUT supply
Other DUT supply voltages on
request
CRO Trigger
15V trigger signal for oscilloscope;
burst duration and pulse frequency
can be checked
TEST ROUTINES
Quick Start
Immediate start; easy to use and fast
User Test routines
Custom made test routine
Change voltage after T
Change frequency after T
Frequency sweep within a burst
Change burst duration after T
Random release of bursts
Synchronous burst mode
Change polarity after T
Standard Test
routines
As per IEC 61000-4-4,
Automatic test Level X - Y
Service
Service, set-up, self test
INTERFACES
Serial interface
USB
Parallel interface
IEEE 488, address 1 - 30
CN interface
To control external CNI 503
GENERAL DATA
Dimensions,
weight
EFT 500N5.1: 19"/6HU, 22kg
EFT 500N5.2: 19"/6HU, 40kg
EFT 500N5.5: 19"/3HU, 20kg
EFT 500N5.8: 19"/3HU, 23kg
Supply voltage
115/230V, +10/-15%
Fuses
2 x T 2AT (230V); 2 x T 4AT (115V)
OPTIONS
HFK
Coupling Clamp as per IEC
61000-4-4
KW 50
50ohm matching resistor for
verification
KW 1000
1,000ohm matching resistor for
verification
CA EFT kit
Kit for burst pulse verification
consisting of KW50, KW1000 and
adapter for DUT port with plastic
case for storage
A6dB
6dB attenuator
CNI 503
Coupling/decoupling networks,
3x440V/32-63-100A
iec.control
Software to control the test,
including standard library, test
report facility and data conversion
generator
www.emtest.com
© EM TEST > PAGE 2/3