beautypg.com

Specifications, Rack mounting, Ordering information – Atec California-Instruments-Omni-3-37i User Manual

Page 2

background image

Rack Mounting

For rack mount applications -

especially three phase systems - the
optional rack mount slides (-RMS)
are recommended. All units provide
carrying handles on the front of the
unit with integrated rack ears.

Ordering Information

Models:

OMNI-1-18i

Reference Impedance network
for 3001i/iX

1

or 5001i/iX

1

single

phase AC source.

OMNI-3-18i

Reference Impedance network
for 15003i/iX

1

three phase AC

source.

OMNI-3-37i

Reference Impedance network
for 30003i/iX

2

three phase AC

source.

Note 1: Models 3001iX, 5001iX and
15003iX provide programmable
impedance (dynamic impedance)
which may be used in lieu of the
OMNI lumped impedance. California
Instruments offers the OMNI option for
those users insisting on the use of a
lumped reference impedance.

Note 2: Model 30003iX does not offer
programmable impedance. The
OMNI-3-37i is required to support IEC
Flicker tests.

Options

-RMS Rack mount Slides. The

use of rack mount slides or a
rack shelf is recommended when
installing the OMNI in a 19” rack.

Line Cord Options:

-PC1

Continental Europe

-PC3

United Kingdom

* One North American right angle Line cord
is included. Optional line cords are straight
which adds about 1 inch of depth.

Supplied with:

North American Line Power

Cord

Rack mount handles

Instruction Manual

Specifications

Input

Line Voltage 115 Vac±10% / 230 Vac±10%

Line Current (typ.) 200 mA @ 115 Vac / 60 Hz

110 mA @ 230 Vac / 50 Hz

Line Frequency 47-63 Hz

Fuse Rating 0.25 A slow acting @ 115 Vac

0.125 A slow acting @ 230 Vac

Output

OMNI-1-18i

OMNI-3-18i

OMNI-3-37i

Phases 1 3 3

Engage/Flicker Mode:

Max. Current 18.5 A 18.5 A / ø 37.0 A / ø

Useable range 2.0 - 18.5 A 2.0-18.5 A / ø 2.0 - 37.0 A / ø

Bypass Mode:

Max. Current 37.0 A 37.0 A / ø 74.0 A / ø

Impedance @ 50 Hz Engage/Flicker Mode:

Phase 0.24 + j0.15

0.24 + j0.15

0.24 + j0.15

Neutral 0.16 + j0.10

0.16 + j0.10

0.16 + j0.10

Accuracy < 5 %

< 5 % < 5 %

Mechanical

Dimensions 3.5” x 19” x 22” 5.25” x 19” x 22”

(H x W x D) 89 x 480 x 560 mm 133x480x560

mm

Weight 31 lbs 37 lbs 62 lbs

14 kg 17 kg 28 kg

Connectors

Input AC IEC 320

Load Input and
Output

Compression terminals

Controls and Indicators

Power On/Off toggle switch

Flicker On/Off push button

Power Led

Bypass mode Led

Flicker mode Led

Contact California Instruments:

Toll-Free: 800-4AC-POWER

800 422-7693

FAX: 858 677-0940

Email: [email protected]

Web page: http://www.calinst.com

9689 Towne Centre Drive, San Diego CA, 92121-1964 (858) 677-9040 FAX : (858) 677-0940

Copyright 1998, California Instruments Corp. Specifications subject to change without notice Printed in the USA. OMNIDS 10/98