206
Input
Voltage Ranges
Factory configured 187 to 264 Vrms, 3ø L-L (3 wire), or 342 to 457 Vrms, 3ø L-L (4 wire). A chassis ground is also required.
Power Factor
PFC Input, 0.99PF
Frequency Range
47 to 440 Hz
Efficiency
70% min, at full load
Ride Through
10 ms minimum
Output
Power
5550 VA: 1ø or 3ø (systems up to 33,000 VA)
AC or DC Output Voltage
0 to156 Vrms L-N, low range; 0 to 312 Vrms L-N, high range
Current Per Phase
16A to 115V in 156V range; 8A to 230V in 312V range per, 1850 VA module.
Power Factor of Load
0 lagging to 0 leading (0-unity)
Crest Factor
3.5:1 (peak output current to rms output current))
Frequency Range
Specifications apply DC, 40Hz to 5kHz. For output frequencies greater than 1 kHz, the max slew rate
allowed is 1 kHz per second.
Max Total Harmonic Distortion
(Full Linear Load or No Load): 0.25% max, 40 to 100 Hz; 0.5% max to 500 Hz; and 1% max to 1 kHz plus 1%/kHz to 5 kHz
AC Noise Level
>60 dB rms below full output voltage
Amplitude Stability With Remote Sense
±0.1% of full scale over 24 hours at constant line, load and temperature
Line Regulation
(DC, or 40 Hz to 5 kHz): ±0.015% of full scale for a ±10% input line change
Load Regulation
±0.025% of full scale voltage for a full resistive load to no load; above 1 kHz, add ±0%/kHz
Voltage Accuracy
±0.1% of range. Above 1 kHz, add 0.2%/kHz. Add ±0.1% of full scale for “AC PLUS DC” mode. Valid for 5 to 156 Vrms and
10 to 312 Vrms at 25°C
Voltage Resolution
1mV (0.1V) Full Scale
Frequency Accuracy
±0.01% at 25°C ±0.001%/°C
Frequency Resolution
40 Hz to 81.91 Hz (0.01 Hz)
81.90 Hz to 819 Hz (0.01 Hz)
820 Hz to 5000 Hz (1 Hz)
Phase Accuracy, Phase-to-Phase
Balanced Linear Resistive Load
±1% of Programmed value
Phase Angle Resolution
0.1°
Remote Output Voltage Sense
5 Vrms total lead drop, max
CSW Series : Product Specifications
Common Intput and Outputs
Remote Inhibit
A logic Low or High contact closure input to inhibit the outputs
External Amplitude Modulation
0 to 5 VRMS provides 0 to 20% output amplitude modulation (±2% of full scale output).
External Drive Input
Acts as Amplifier, 0 to 5 VRMS (DC to 5 kHz) or ±5 VDC input for zero to full scale programmed voltage output
(±2% of full scale output). Individual inputs for an external signal for each of the three phases.
Remote Programming Voltage
0 to ±7.07 VDC provides zero to full scale programmed voltage output
(±2% of full scale output).
External Input Impedance
40K (ohm symbol) for each of the three inputs.
Externaly Sync
External Sync allows the output frequency of the AC source to be synchronized to an external TTL level clock signal.
LKM
Clock and Lock Master. Enables synchronizing outputs of two or more California Instruments sources, one acts as master.
LKS
Clock and Lock Auxiliary
Front Panel Trigger, BNC Connector
Output available at the front panel BNC connector that provides a negative going pulse for any programmed voltage or frequency
change. The trigger can be reassigned as an output when running list transients.
Front Panel Phase A, B and C,
BNC connectors
These three outputs are representive of the programmed output waveform, magnitude and frequency. 0 to 4.86 Vrms represents 0 to
a full-scale output voltage.