DATA SHEET > CWS 500N4 > 20121113
TECHNICAL DETAILS
GENERAL DATA
INTERFACE
Serial interface
USB
Parallel interface
IEEE 488, addresses 1 - 30
Fail 1
BNC input; test will be stopped
immediately (when input becomes
active low)
Fail 2
BNC input; test will be stopped
(when input becomes active low) and
contiunued (input active high). After
10 fail events the test will be
stopped.
GENERAL DATA
Dimensions
19"/6HU,
555mm x 448mm x 286mm
Weight
Approx. 30kg
Supply voltage
115V - 230V +10/-15%, 50/60Hz
Input power
Max. 600W
Fuses
2x6.3AT (115V) or 2x3.15AT (230V)
2x10AT for AC-source
Cooling
Active cooling, air ventilation
Temperature
10°C - 40°C
OPTIONS
ACCESSORIES COUPLING NETWORK
CN 16-L2/L4
2-wire/4-wire coupling network,
switchable,
EUT Umax. AC: 440V 16.7Hz..60Hz
EUT Umax. DC: 125V
GEN IN Umax.: 330V AC/DC
Power dissipation: max. 40W
CN 16-L2.1
2-wire coupling network,
EUT Umax. AC: 300V 16.7Hz..60Hz
EUT Umax. DC: 220V
GEN IN Umax.: 330V AC/DC,
Power dissipation: max. 200W,
active cooling,overtemperature
protection,
Mains: 85-265V AC 50/60Hz, Fuse
1AT
CN 16-L3
3-wire coupling network,
EUT Umax. AC: 440V 16.7Hz..60Hz
EUT Umax. DC: 125V
GEN IN Umax.: 330V AC/DC
Power dissipation: max. 40W
CN 16-L4/690V
4-wire coupling network,
EUT Umax. AC: 3x690V 50/60Hz
EUT Umax. DC: 125V
GEN IN Umax.: 330V AC/DC
Power dissipation: max. 40W
CDN 16-L4/400V
4-wire coupling network, decoupling
with isolation transformer
EUT Umax./ Imax.: 3x400V 16A
GEN IN Umax.: 330V AC/DC
CN 16-L8
8-wire coupling network,
EUT Umax. AC: 300V 16.7Hz..60Hz
EUT Umax. DC: 160V
GEN IN Umax.: 330V AC/DC,
Power dissipation: max. 40W
CDN 16-T2
Telecom T-network, 60 VDC, 2A
EUT Umax.: 60V DC
EUT Frequency range: Telecom
applications
GEN IN Umax.: 330V AC/DC
CN 60255-22-7
4-wire coupling network as per IEC
60255-22-7, figs. 2, 3 and 4,
common mode and differential mode
coupling
CN 61543
Coupling network as per IEC 61543
(100ohm)
www.emtest.com
© EM TEST > PAGE 3/5