DATA SHEET > CWS 500N4 > 20121113
TECHNICAL DETAILS
TESTING AS PER IEC/EN 61000-4-16
OUTPUT CHARACTERISTICS CONTINUOUS MODE
Test frequencies
DC, 16 2/3Hz, 50Hz and 60Hz
Signal level
0.1 - 35Vrms or DC
Test level 1
1V continuous
Test level 2
3V continuous
Test level 3
10V continuous
Test level 4
30V continuous
Output impedance
50ohm ± 10%
Total harmonics
distortion
< 10% (sinusoidal waveform)
Ripple on DC
< 5%
OUTPUT CHARACTERISTICS SHORT-TERM MODE
Test frequencies
DC, 16 2/3Hz, 50Hz and 60Hz
Signal level
1 - 330Vrms or DC
Test level 1
10V for 1s duration
Test level 2
30V for 1s duration
Test level 3
100V for 1s duration
Test level 4
300V for 1s duration
Output impedance
50ohm ± 10%
Total harmonics
distortion
< 10% (sinusoidal waveform)
Phase
synchronisation
0° ± 5%
Ripple on DC
< 5%
Fall/rise time
between 1us and 5us
Note:
These tests require either the
optional MV 2606N2.2 motor variac
or the optional programmable AC
voltage source ACS 500N2.3.
TESTING AS PER IEC/EN 61000-4-16
OUTPUT CHARACTERISTICS 15HZ - 165KHZ
Frequency range
10Hz to 165kHz
Signal level
0.1 to 35Vrms
Test level 1
1V - 0.1V - 1V
Test level 2
3V - 0.3V - 3V
Test level 3
10V - 1V - 10V
Test level 4
30V - 3V - 30V
Output impedance
50ohm ± 10%
Total harmonics
distortion
< 1% (sinusoidal waveform)
MEASUREMENT
Voltage
internal rms measurement
TEST ROUTINES
Quick Start
Immediate start; easy to use and fast
discrete frequency testing
Service
Service, Set-up
TESTING OF ELECTRICITY METERING
EQUIPMENT AS PER TR-EN 50579
INTERFERENCES DISTURBANCES TESTING AS PER TR-EN
50579 AND IEC 61000-4-19 ANNEX C (OPTION)
Test frequencies
2kHz to 150kHz
Signal level
Max. 3A up to 150kHz
Total harmonic
distortion (THD)
<5% at maximum level
Accuracy
better than ± 5%
Frequency step
Max. 1%
Output impedance
1.0ohm (external decoupling
impedance SH 1R)
www.emtest.com
© EM TEST > PAGE 2/5