Atec AR-CI00401A User Manual
Atec Equipment
Approved for public release by AR RF/Microwave Instrumentation
092412
160 School House Road Souderton, PA 18964-9990 • 215-723-8181 • www.arworld.us
Page 1 of 2
Model CI00401A, M1, M2
RF Conducted Immunity System
150 Watts
100 kHz–400 MHz
Complete Testing Solutions to the following standards:
ISO 11452-4
GMW 3097
ES-XW7T-1A278-AC
DC-11224
BMW GS95002
Peugeot B217110
Renault 36-00-8081-G
IEC 61000-4-6
Other automotive standards
The Model CI00401A is a fully self-contained state of the art system
designed to test RF Conducted Immunity. The CI00401A contains all the
instruments needed to perform conducted immunity testing for automotive
and IEC specifications. The system contains a signal generator, three channels of power monitoring, 150W AR amplifier
100 kHz to 400 MHz, directional coupler, and emcw
ar
e® control software. Everything is contained in a single housing,
which eliminates setup issues. This system provides the versatility needed for every test laboratory and equipment
manufacturer. The RF amplifier and the signal generator can be used independently of the system. If special needs arise
or standards were to change, a larger amplifier can be connected to the system. The use of spectrum analyzers and
monitoring equipment may also be controlled by the software.
The export classification for this equipment is EAR99. These commodities, technology or software are controlled for export
in accordance with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited.
Internal Test Specifications (See Note 1)
ISO 11452-4
GMW 3097
ES-XW7T-1A278-AC
DC-11224
BMW GS95002
Peugeot B217110
Renault 36-00-8081-G
IEC-61000-4-6
Other automotive standards
Signal Generator Specifications
Frequency range
resolution
9 kHz to 1.2 GHz
1Hz
Power range
resolution
-140 to +13 dBm
0.1 dB
Modulation
AM, FSK. FM, Phase, External Pulse
Power Meter Specifications (See Note 2)
Power heads
3
Type
Diode
Frequency
10 kHz to 8 GHz
Range
-60 to +20 dBm
RF Amplifier Specifications
Frequency range
100 kHz to 400 MHz
Power rating
150 Watts Minimum
1dB compression
120 Watts Minimum
Harmonic Distortion
-20 dBc at 120 Watts
Mismatch tolerance
100% of rated power without
fold back. Will operate without
damage or oscillation with any
magnitude of source and load
impedance.
Gain
52 dB minimum
NOTE 1: Specifications can be met using AR-specified external accessories (injection probes, monitor probes, cal fixtures, CDN’s,
attenuators, etc.) Contact AR for further information.
NOTE 2: The use of a spectrum analyzer may be necessary on some of the low level bulk current injection tests. This is especially true on
power and I/O lines with a great amount of ambient noise.