beautypg.com

Features, Applications, Model 1060 includes these additional features – Atec AEMC-1050 User Manual

Page 2

background image

1000V Digital/Analog Megohmmeter Models 1050 & 1060 (pdf)

Rev. 05

01/05

Technical Assistance (800) 343-1391

www.aemc.com

2 of 9

FUNCTION

MODEL

MODEL

1050

1060

50V (0.002Mto 200G)

100V (0.004Mto 400G)

250V (0.01Mto 1T)

500V (0.02Mto 2T)

1000V (40kto 4T)

Voltage Test/Safety Check (600V

AC

/

DC

)

Guard Terminal

Continuity (40) @200mA

Resistance (400k)

Lead Compensation

Backlight

Timer (1–59 minutes)

Digital Dual Display

Analog Bargraph

Auto-Off

Continuity Buzzer

Continuity Buzzer Disable

Voltage Detection (>25V)

Safety Test Inhibitor

Automatic Discharge

Rechargable NiMH Battery

AC Supply 85-256V/50/60Hz

Battery Powered

Battery Capacity (%) Indication

Auto-Off Disable

Automatic DAR/PI

Smooth Function

Memory Storage (128kB)

Report Printout on Serial Printer

RS-232 Communication

Features

True Megohmmeter

®

Test voltage combinations of 50V, 100V, 250V,
500V and 1000V

Insulation measurements to 4000G

(4T

)

Direct measurement of DAR and PI values

Direct measurement of sample Capacitance

Display of test voltage and run time

Programmable test run times and PI times

Smooth and Alarm functions

Automatic test inhibition (if live sample >25V)

Automatic discharge after use with voltage display

Large dual display with time, voltage and measurement

Bright blue electroluminescent backlight

Battery powered

Auto power-down when not in use

Remote operation with optional test probe

Rugged dual wall field case with detachable lead/
accessory pouch

EN 61010-1, 600V Cat. III, EN 61557

CE Mark

Model 1060 includes these
additional features:

AC rechargeable NiMH batteries – run while recharging

RS-232 interface for direct printing of results (serial output)

128kB memory to store measurements in specific files

Remote operation of megohmmeter through PC

Includes DataView

®

software for data storage, real-time

display, analysis and report generation

Applications

Test insulation on cables, transformers, motors, insulators
and wiring installations

High resistance or absorption tests

Spot reading tests

Timed resistance measurements

Dielectric Absorption Ratio (DAR) and
Polarization Index (PI) tests

Low insulation test range for testing old or flooded
installations

Motor insulation resistance measurements

Continuity checks and low resistance measurements

Computer controlled production line testing

Predictive maintenance by storing results in PC for
trend analysis

Model 1060 checking insulation resistance between windings on a
three-phase motor.