PROFITEST PV
Peak Power Measuring Instrument and Curve Tracer for
PV Modules and Strings (Measurement at Capacitive Load)

2

GMC-I Messtechnik GmbH

Regulations and standard in accordance with which the test instrument is
manufactured and tested:

Regulations and Standards for Use of the Test Instrument

Characteristic Values

The measuring ranges can be combined with each other. The
measuring instrument automatically selects the ideal measuring
range.

Computer Unit

Miniature industrial PC, real-time clock, no moving mechanical
parts such as hard disks, fans etc.
A-D sampling rate: max. 100 kHz, resolution: 12 bit
Measuring accuracy for characteristic I-U curve better than 1%,
peak power ±5%
Data from several thousand measurements are automatically
saved at the device permanently (flash memory)

Measuring Unit

Sampling rate

Max. 100 kHz,

Resolution

0.01 to 0.25 V, 0.005 to 0.001 A
(depending on selected measuring range)

Measuring accuracy

Better than 1%

Ascertainment of Peak Power

Tolerance

±5%

Reproducibility

±2%

Measurement duration for separate measurement of individual
modules: > 20 ms (approx. 100 pairs of measured values), and
thus the capacitive characteristics of the device under test have
no influence on measurement.

4-conductor measurement cable to the generator prevents
systematic voltage measuring errors

Irradiation reference sensor (Phox) with integrated Pt1000
temperature sensor

Supplementary measurement of temperature at the back of
the module is possible (a second Pt100 input is provided)

Commercially available reference sensors such as the ISET-
Sensor

®

can be connected via interference-free cable con-

nection

Connection is only permissible to direct voltage sources with
current limiting (e.g. photovoltaic generators)

Sensor Connection Pin Allocations

Temperature (external): 4 pin female chassis socket, Lumberg KFV40
Pin 1: current source + (~1 mA)
Pin 2: Pt100 +
Pin 3: Pt100 –
Pin 4: current source – (~1 mA)

Irradiance: 8 pin female chassis socket, Lumberg KFV81 (plug: SV81)
Pin 1: irradiance +
Pin 2: Pt1000 (reference) +
Pin 3: irradiance –
Pin 4: current source + (~1 mA)
Pin 5: current source – (~1 mA)
Pin 6: unused (do not connect)
Pin 7: unused (do not connect)
Pin 8: Pt1000 (reference) –

Ambient Conditions

Accuracy

0 to + 40

° C

Operation

0 to + 40

° C

Storage

–10 to + 85

° C (without batteries)

Relative humidity

Operation

10 to 90% (non-condensing),
no condensation allowed

Storage

5 to 95%
no condensation allowed

Power Supply

Rechargeable batteries Lead-acid, 12 V / 3.4 Ah

(continuous operation: approx. 3 hr.),

Power consumption

Approx. 40 W

External power pack

In: 90 to 263 V AC, 47 to 63 Hz, 40 W,
Out: 16 V DC

UL approval

Integrated charge controller for protection against overcharging
and excessively depleting the batteries

Charge level indication by means of LED on the housing
(status display on the PROFITEST PV)

IEC 61010-1/EN 61010-1/
VDE 0411-1

Safety requirements for electrical equipment for
measurement, control and laboratory use
– General requirements

EN 60529
VDE 0470, part 1

Test instruments and test procedures
Degrees of protection provided by enclosures (IP code)

DIN EN 61326-1
VDE 0843-20-1

Electrical equipment for measurement, control and
laboratory use –
EMC requirements – Part 1: General requirements

IEC 62446
VDE 0126-23

Grid connected photovoltaic systems –
Minimum requirements for system documentation,
commissioning tests and inspection

Standard Measuring Ranges

Voltage
[V]

Current
[A]

Temperature

Irradiation

25, 100, 500, 1000 2, 5, 10, 20

-40 to +100° C

with Pt1000

0 to 1300 W/m²
(standard sensor)