Specification – Atec Biddle-CFL535E User Manual
Page 2
Trace Master PC Software
Trace Master provides download and upload facilities
between the TDR and a computer. Traces can be individually
selected, saved to a PC and annotated by the user. Historical
information can be reviewed on the PC or recalled to the
TDR for comparison with current measurements.
Tracemaster is the ideal tool for cable documentation.
Results can be printed from the computer for inclusion in
documents.
Power source
The TDR2000/2P is supplied with a NiMH rechargeable
battery pack and charger as standard.
Further benefits:
n
11 fault location modes.
n
For use 300V CAT III (415V phase to phase) power
circuits with fused leads.
n
External mains blocking filter not required.
n
Screen contrast control.
n
Multi language operation, uploadable using TraceMaster
software.
n
3 step pulse amplitude control.
n
Adjustable display contrast.
n
15 trace internal memory.
n
Protected to IP54.
n
High impact ABS case.
n
Comes with test and carry case and test leads.
n
3 year warranty
SPECIFICATION
Except where otherwise stated, this specification applies at an
ambient temperature of 20 °C.
General
Ranges:
50 m, 100 m, 200 m, 400 m, 1 km, 2 km, 4 km, 8 km, 16 km.
150 ft, 300 ft, 600 ft, 1200 ft, 3000 ft, 6000 ft, 12000 ft, 2400 0ft,
48000 ft
Resolution:
0.1 mm (4 inches) up to 200 m
0.2 m up to 400 m
0.1% of range above 400 m
Measurement Accuracy: 0.1% of Range
[Note – The measurement accuracy is for the indicated cur-
sor position only and is conditional on the velocity factor being
correct].
Input Impedance: Automatic 0 to 120 Ω
Input Protection: 300 V CATIII phase to ground
(440 V phase to phase) working.
Output Pulse Amplitude:
Nominal 3 V, 5 V and 14 V pk to pk
into an open circuit
Pulse width user selectable:
50 m range:
7 ns, 20 ns, 40 ns, 60 ns, 80 ns
100 m range:
7 ns, 40 ns, 60 ns, 80 ns, 100 ns
200 m ranges:
7 ns, 40 ns, 80 ns, 14 0ns, 200 ns
400 m range:
40 ns, 80 ns, 160 ns, 200 ns, 400 ns
1 km range:
80 ns, 160 ns, 260 ns, 500 ns, 1 µs
2 km range:
160 ns, 260 ns, 500 ns, 1 µs, 2 µs
4 km range:
240 ns, 500 ns, 1 µs, 2 µs, 4 µs
8 km range:
500 ns, 1 µs, 2 µs, 4 µs, 8 µs
16 km range:
1 µs, 2 µs, 4 µs, 8 µs, 16 µs
(Default pulse width for each range
underlined)
Gain:
0 to 90 dB in steps of 6 dB
TX Null:
0 Ω to 120 Ω
Velocity Factor:
Variable from 0.300 to 0.999 in steps of 0.001
Screen Update Rate:
Once per second or three times per second, (user selectable).
Power Down:
Automatic after 5, 10 or 15 minutes with no keys pressed, (user
selectable)
Backlight:
Stays on for 1, 2 or 5 minutes when activated, (user selectable).
Communications Port:
RS-232C compatible - 1 start bit, 8 data bits, 1 stop bit and no
parity, 19200 baud standard
Internal Memory: Storage capacity of 15 waveforms and data.
Batteries:
TDR2000/2P
9.6 V NiMH cell
TDR2000/2P
Dual channel Cable Fault Locator