beautypg.com

Product application – Atec Chroma-19032 User Manual

Page 4

background image

SAFETY TEST OF INFORMATION TECHNOLOGY PRODUCT (IEC 60950)

POWER SUPPLIES, ADAPTER AND CHARGER SAFETY TESTING

Product Application

In digital time, information technology is so close to our life. Desktop,
notebook, LCD monitor, UPS, printer and projector are the products that
human may use at any time. To ensure the safety, all products should
do electrical safety test. The 19032 offers all functions of safety tests
and Normal/Reverse as well as Single Fault switch function (LC Test) to
reduce the load of manufacturing personnel.

Besides, the output floating of Telecommunication Network in IEC 60950
to perform dynamic leakage current test is required. The equivalent
stray capacitance will also be generated on isolated transformer even
it is floating circuit. The stray capacitance results in leakage current,
electrical damage to users. The 19032 along with 6000-05 /07/08
leakage current scanner have P1/P2 measurement function which is
able to measure dynamic leakage current on output terminal. It is the
best solution for testing information technology products.

Main Test Item
• Open Short Check
• Ground Bond
• AC/DC Hipot Test
• Earth Leakage Current Test
• Output Leakage Current Test

Power supply of electronic products including SMPS, Adapter and charger need to perform electrical safety test. According to various power

design methods and test conditions, the 19032 offers programmable edit and solution to let you complete all tests at one time.

A lot of designs of power product, the insulation capability of input terminal (Primary) to output terminal (Secondary) is required to protect the

damage inside component. Thus, the output terminal of Floating needs to perform Hipot test. The 19032 provides isolation test point with high

voltage which allows you not to change the fixture or cable manually but perform P-S Hipot test directly after P-G Hipot test.

Moreover, if there is danger to touch output

terminal (Secondary), dynamic leakage current

test also needs to be performed.

Test item

Power supply sources

Open

&

Short

(OSC)

Ground

Bonding

Withstanding

voltage

from primary

to

Ground

Withstanding

voltage

from primary

to

Secondary

Leakage

Current

Three-wire power supply
class 1 (Secdonary Floating)

V

V

V

V

V

Three-wire power supply
class 1

V

V

V

-

V

Two-wire power supply
class 2

V

-

-

V

V

LIGHTING INDUSTRY AND LED RELATED ELECTRICAL SAFETY TEST

LED on the lighting industry is widespread gradually in the daily life. Each LED and power product need to be tested for withstand voltage,
insulation, grounding resistance and leakage current for protection from personal electric shock hazard.

Test item

Test Condition

Leakage Current Test

IEC 60990,Measure network Figure4,Configuration Figure 6

Withstanding Voltage Test

Working voltage<DC42V

WV Test Voltage 500V

Working voltage≧DC42V

WV Test Voltage (2U+1000)V

Ground Bonding Test

Current from AC source of 25A passed for 1min between earthing

terminal and each of the accessible metal parts(IEC 61347-1)

LED Driver / Power Supply

AC

Line

L

N

Ground
Bound

Leakage
Current

Withstand
Voltage

PE

Electronic

Circuit

Transformer

N

AC MAINS

SUPPLY

C

I

C

IEC 469/99

N

L

T

Optional Test

Transformer

for Isolation

(Earthing Conductor)

B

A

Measuring Network

PE

N

L

e

P1

(Polarity)

Point of connection to AC MAINS SUPPLY

EUT

(Test Switch)

P2

(Polarity)

Telecommunication

Network Connection

Port (not connected)

S

Chroma19032 with 4HV/4GC Scanner