AC/DC/IR HIPOT TESTER
MODEL : 19071/19073

Complete Dielectric Testing Solution
The Chroma Hipot Tester 19070 series
provide 3 models for choice. The 19071 for
AC Hipot testing, the 19073 which combines
both AC and DC Hipot with insulation
resistance (IR) measurements into a single
compact unit. The front panel of the testers
make them easy to operate. The digital
display and user friendly control allow test
parameters and limits to be set easily without
activating the high voltage.

The 19070 series electrical safety tester are
advanced digital hipots with load and line
regulation to ensure the measurement
integrity. Multi-step capability allows users to
perform up to two tests in a sequence such
as AC hipot followed by IR.

The 19071 AC Hipot Tester performs AC
dielectric withstand (hipot) tests. The test
voltage can be programmed in the range of
50V AC to 5kV AC with a resolution of 1V. Its
maximum total output current is 15mA.

The 19073 AC/DC/IR Hipot Tester has all the
features of the 19071 plus measurement of
insulation resistance. The IR measurement
range is from 1MΩ to 10GΩ with test voltages
from 50 to 1000V DC.

Ground Fault Interrupters (GFI)
GFI is required by the National Electrical
Code in wet locations. Such devices
automatically interrupt power when a ground

current >0.5mA exists for more than a few
milliseconds to protect users.

Quick Discharge
In DC hipot and IR the device under test is
discharged back through the HV transformer.
This technique results in a rapid and safe
discharge.

Ground Continuity Check
All of the 19070 Series testers have a ground
continuity check feature to determine that the
resistance, that is between the ground blade
of power cord and any exposed metal on the
product,is less than 1Ω.

Arc Detection
The 19070 series are sensitive enough to
monitor 10µsec current spikes even if they do
not exceed the maximum trip current level.

Large LCD display
Users can easy to operate instrument with
great view of setting functions and test result .

Ground fault interruption shutdown

the instrument when imbalance

current > 0.5mA , provide the

highest protection capability

TUV approved

CE Certified

Programmable output voltage up to

5kV AC and 6kV DC

Insulation resistance measurements from

1MΩ to 50GΩ

Ground continuity check with 1Ω limit

Arc detection with programmable limit

Front panel lockout

Large LCD display (240 x 64dot matrix)

can supply great view of test result and

setting functions

Programmable ramp and test times

Programmable high and low limits

Cost effective solution for Hipot and IR

Quick discharge of DUT in IR and DC

Hipot

Storage of 10 test setups with 60 steps

per setup

Remote control

Easy to use

MODEL 19071

19073

AC/DC/IR Hipot Tester

Key Features :