background image

Dash 18X: Features 18
channels of universal
inputs, data acquisition
to internal hard drive at
100 kHz sample rate
per channel.

Dash 8Xe: Features 8
channels of modular
inputs, data acquisition
to internal hard drive
at 200 kHz sample rate
per channel.

OTHER EXCITING PRODUCTS AVAILABLE FROM ASTRO-MED

World Headquarters

Astro-Med Industrial Park
West Warwick, Rhode Island 02893 U.S.A.
Phone (401) 828-4000 • Fax (401) 822-2430
E-mail: [email protected]
Web Site: www.astro-med.com
Toll-Free Phone (U.S.A. only):
(877) 867-9783

Astro-Med is system certified to ISO9001.

083006

FACTORY SALES AND SERVICE CENTERS
CANADA
• Astro-Med, Inc., 648 Rue Giffard
Longueuil, QC J4G 1T8 Canada • Tel. (450) 651-7973 / Fax (450) 651-8987
Toll-Free Phone (Canada only): (800) 565-2216
UNITED KINGDOM • Astro-Med House, 11 Whittle Parkway
Slough, Berkshire SL1 6DQ • Tel. 01628 668836 / Fax 01628 664994
FRANCE • Astro-Med SNC, Parc d’Activités de Pissaloup, 1 Rue Edouard Branly,
78190 Trappes • Tel. (+33) 1 34 82 09 00 / Fax (+33) 1 34 82 05 71
GERMANY • Astro-Med GmbH, Senefelderstrasse 1/T6 D-63110 Rodgau
Tel. +49(0)6106-28368-51 / Zentrale 28368-0 / Fax +49(0)6106-771121
ITALY • Astro-Med S.R.L., Via Plezzo 8, 20132 Milano
Tel. (+39)-02-26411909 / Fax (+39)-02-26412828

S P E C I F I C A T I O N S

Color Display

Display

Full screen waveform or split screen
w/analysis

Waveform display

Voltage/current or phase groups

Viewing area

15-inch diagonal with 1024 x 768
resolution

Touch screen

Full-screen, resistive

Signal Modules

Maximum modules

8 per unit

Supported modules

IHV1 – voltage/current phase
IHV2 – voltage phase

Channels

4 voltage, 4 current (when no
auxiliary channels are used)

Auxiliary channels

Modules 7 and 8

IHV1 Module

Maximum voltage

250Vrms CAT II

Bandwidth

39 kHz

IHV2 Module

Maximum voltage

600Vrms CAT II, 300Vrms CAT III

Bandwidth

34 kHz

Continuous Recording

Recording method

Internal disk drive

Sample rate

6,250 samples per second per
channel

Drive capacity

73 GByte

Continuous Recording time

up to 88 hours (dependent on free
disk space)

Recorder Mode

Analysis

Real-time calculations

Continuous recording

All waveforms with one-button
start/stop

Event logging

Simultaneous with continuous
waveform recording

Review Mode

Analysis

Post-capture calculations

Derived channels

Graphic plots of trend data. Includes
Vrms, Irms, apparent power, real
power, reactive power, power factor,
frequency, THD, voltage unbalance
and current unbalance

Transient Mode

Sample rate

200,000 samples per second per
channel

Event Logging

Yes

Logged Event Types

Voltage

Interrupt, sag, swell, transient,
frequency, total harmonic distortion,
individual harmonic, individual
interharmonic, unbalance

Current

Transient, RMS thresholds, total
harmonic distortion, individual
harmonic, individual interharmonic,
unbalance

Power

Power factor, absolute power, active
power, reactive power, leading/lagging

Analysis Functions

Harmonics/Interharmonics

Graphical display for any phase
(voltage or current); total harmonic
distortion percentage

Phase diagrams

Vector diagrams for voltage and
current

RMS values

Calculated for all phases, voltage and
current

Power values

Absolute power (kVA), active power
(kW), reactive power (kVAR) and
power factor

Sequential components

Positive, negative, and zero sequence;
voltage or current; percentage
unbalanced

Power

Input Voltage Range

102 to 264 VAC

Frequency Range

47 Hz to 63 Hz

Power Factor

0.99

Power Consumption

150 W maximum (<100 W typical)

Physical

Enclosure

Aluminum

Dimensions

12.6" H x 16.7" W x 4.5" D

Weight

22 lbs (with 8 modules)

Environmental

Operating Temp

5 to 40°C (40 to 105°F)

Operating Humidity

10% to 90% non condensing

Specifications subject to change.

All registered trademarks belong to their respective companies.

Dash 8HF: Features 8
channels of analog inputs,
data acquisition to internal
hard drive at 2 MHz
sample rate and 200 kHz
bandwidth.