beautypg.com

Configuration guide dewe-2602, Typical configurations, Dewe-2600 – Atec Dewetron-DEWE-2600 User Manual

Page 3: Dewe-2602, Dewe-2601

background image

1.5 U

2 U

1.5 U

2 U

2 U

0.5 U

1 U

1 U

1.5 U

101

Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2

All-In-One

Analog input - DAQ modules

Configuration Guide DEWE-2602

This version combines slots for

isolated DAQP modules and positions for differential MDAQ blocks. Thus it enables

you configuring a cost optimized system that needs isolated inputs, e.g. high voltage signals, and a number of dif-
ferential inputs, e.g. accelerometers.

Options

MDAQ panels

Counter input with digital input

1.5U-ORION-DIO-PANEL-1

Analog output

0.5U-AOUT-BNC-2

1U-AOUT-BNC-4

1U-AOUT-BNC-8

Analog input - MDAQ modules

Typical Configurations

Thermocouple inputs via 4 MPAD-TH-8

1.5U-TC-PANEL-32

DEWE-2600

16 isolated DAQP modules
4 MPAD modules

(16 tc “T” and 16 tc “J” inputs)

8 counters + 16 extra digital input

DEWE-2602

16 isolated DAQP modules
16 differential analog MDAQ inputs
8 counters + 16 extra digital inputs

DEWE-2601

80 differential analog MDAQ inputs

0.5 U

0.5 U

Power supply for PNA-A100
current clamps

±15 V power supply and digital status
lines for PNA-CLAMP-150-DC

0.5U-AMPFLEX-POWER-8

0.5U-CLAMP-DC-POWER-8