Noise figure analyzers – Atec Agilent-N8972A_N8973A_N8974A_N8975A User Manual
Page 3
10 MHz to 1.5 GHz, 3 GHz, 6.7 GHz and 26.5 GHz Noise Figure Analyzers (cont.)
Noise Figure Analyzers
N8972A
N8973A
N8974A
N8975A
General Specifications
Dimensions
Without handle: 222 mm H x 375 mm W x 410 mm D
With handle (max): 222 mm H x 409 mm W x 515 mm D
Weight (typical, without options)
N8972A: 15.3 kg
N8973A: 15.5 kg
N8974A: 17.5 kg
N8975A: 17.5 kg
Data Storage (nominal)
Internal drive: 30 traces, states or ENR tables
Floppy disk: 30 traces, states or ENR tables
Power Requirements
On (line 1): 90 to 132 V rms, 47 to 440 Hz, 195 to 250 V rms, 47 to 66 Hz
Power consumption: <300 W
Standby (line 0): <5 W
Temperature Range
Operating: 0ºC to +55ºC
Storage: –40ºC to +70ºC
Humidity Range
Operating: Up to 95% relative humidity to 40ºC (non-condensing)
Altitude range: Operating to 4,600 meters
Calibration Interval
1-year minimum recommended
Electromagnetic Compatibility
Complies with the requirements of the EMC directive 89/336/EEC. This
includes Generic Immunity Standard EN 50082-1:1992 and Radiated
Interference Standard CISPR 11:1990/EN 55011:1991, Group 1 Class A.
The conducted and radiated emissions performance typically meets
CISPR 11:1990/EN 55011:1991 Group 1 Class B limits.
Warranty
3-Year warranty as standard
Key Literature
Noise Figure Analyzers, NFA Series, Brochure, p/n 5980-0166E
Noise Figure Analyzers, NFA Series, Data Sheet, p/n 5980-0164E
Noise Figure Analyzers, NFA Series, Configuration Guide, p/n 5980-0163E
Fundamentals of RF and Microwave Noise Figure Measurements,
App note 57-1, p/n 5952-8255E
Noise Figure Measurement Accuracy, App note 57-2, p/n 5952-3706
10 Hints for Making Successful Noise Figure Measurements,
p/n 5980-0228E
N8972A and N8973A, NFA Series, Noise Figure Analyzer Programming
Examples, p/n 5968-9498E
Ordering Information
N8972A 10 MHz to 1.5 GHz NFA Series Noise Figure Analyzer
N8973A 10 MHz to 3.0 GHz NFA Series Noise Figure Analyzer
N8974A 10 MHz to 6.7 GHz NFA Series Noise Figure Analyzer
N8975A 10 MHz to 26.5 GHz NFA Series Noise Figure Analyzer
All options, other than those marked with *, can be ordered at any time for
use with an instrument.
Frequency Reference
N897xA-1D5 NFA series high stability frequency reference*
Calibration Documentation
N897xA-A6J NFA series ANSI Z540 compliant calibration with test data*
Accessories
N897xA-1CP NFA series rackmount and handle kit
N897xA-UK9 NFA series front panel cover
N897xA-1FP NFA series calibration, performance verification and
adjustment software
Documentation
A hard copy and CD version of the English language Quick Reference
Guide, User’s Guide, Programmers Reference, and Calibration and
Performance Verification Manual are included with the NFA as standard.
Selections can be made to change the localization of the manual set or to
delete the hardcopy.
N897xA-AB0 NFA series manual set for Taiwan – Chinese localization
N897xA-AB1 NFA series manual set – Korean localization
N897xA-AB2 NFA series manual set – Chinese localization
N897xA-ABE NFA series manual set – Spanish localization
N897xA-ABF NFA series manual set – French localization
N897xA-ABZ NFA series manual set – Italian localization
N897xA-ABD NFA series manual set – German localization
N897xA-ABJ NFA series manual set – Japanese localization
N897xA-0B0 Delete hardcopy manual set*
Note: The localized options will include a localized version of the Quick Reference Guide
and User Guide, and an English language version of the Programmers Reference, and
Calibration and Performance Verification Manual.
Additional Documentation
N897xA-0B1 NFA series manual set (English version)
N897xA-0B2 NFA series user manual (English version)
N897xA-0BF NFA series programmers reference (English version)
Service Options:
Warranty and Service
Standard warranty is 3 years.
For warranty and service of 5 years, please order R-51B-001-5F: “3 year
Return-to Agilent warranty extended to 5 years” (quantity = 1).
Calibration
2
For 3 years, order 36 months of the appropriate calibration plan shown
below. For 5 years, specify 60 months.
R-50C-001 Standard calibration plan*
R-50C-002 Standard compliant calibration plan*
2
Options not available in all countries