beautypg.com

Characteristics – Atec Agilent-E6008B User Manual

Page 2

background image

2

Characteristics

Horizontal Parameters

Start-km: 0 km to 400 km

Span: 0.1 km to 400 km

Readout resolution: 0.1 m

Minimum sample spacing: 4 cm

Refractive index: 1.00000 to 2.00000

Length unit: km, ft, or miles

Measurement points: up to 64000

Vertical Parameters

Vertical scale: 0.1 to 10.0 dB/Div

Read-out resolution: 0.001 dB

Reflectance range: –14 dB to –60 dB

Backscatter coefficient: 10 to 70 dB

at 1

µs

Pulsewidth

You can select any of the following
pulsewidths:

• 10 ns, 30 ns, 100 ns, 300 ns, 1 µs, 3 µs,

and 10

µs (all modules). You can also

select 5 ns for E6003C, 5A, 9A
modules, and 20

µs for E6003B,

E6003C, E6008B, and E6013A.

With the E6005A module, you can select a
pulsewidth from 5 ns to 100 ns at 850 nm,
and from 5 ns to 10

µs at 1300 nm.

With the E6009A module, you can select a
pulsewidth from 5 ns to 100 ns at 850 nm,
and from 5 ns to 1

µs at 1300 nm.

Storage

3.5” floppy disk drive: for high density

720/1440 kByte floppy disks. MS-DOS
format compatible. Reduced operating
temperature of 5°C to 45°C, with 35%
to 80% humidity at 40°C.

Memory Card: PCMCIA Type II.

440 MB with up to 13000 traces
(typical with 64000 data points).

Internal memory: SRAM up to 2 MB.

Up to 300 traces(typical) with 4000
data points

OTDR Trace Formats

Trace format: compliant to the

following Bellcore/Telcordia OTDR
trace formats:

− GR 196, Revision 1.0

− GR 196, Revision 1.1

− SR-4731 Revision 2.0.

Trace Information: 5 comment labels

of up to 15 alphanumeric characters,
and 5 comment fields of up to 41
alphanumeric characters are provided
for each trace.

• Real-time clock and date

Scan Trace

Type of events: reflective and non-

reflective.

Maximum number of events: 100.

Threshold for non-reflective

events: 0.0 to 5.0 dB, selectable
in 0.01 dB steps.

Threshold for reflective events:

–14.0 to –65.0 dB,
selectable in 0.1 dB steps.

Threshold for fiber breaks:

0.1 to 10 dB, selectable in 0.1 dB
steps.

Fiber End Threshold: 0.1 to 20 dB,

selectable in 0.1 dB steps.

Display

Color or monochrome VGA-LCD:

18.3 cm (7.2”)

Display points: 640 x 480 Points

Measurement update rate:

two measurements per second in
refresh mode

Interfaces

RS232C:

Maximum transmission rate:
115200 bps
Transmission time at 115200 bps for
trace data: 4000 points at approx.
1 second; 64000 points at approx.
4 seconds.

Centronics: Standard parallel port

(SPP).

Keyboard: PS2 (Min-DIN). For English

Standard, PS2, or AT keyboard.

General

• Automatic setup analysis

Instrument settings: storage and

recall of user-selectable instrument
settings.

Laser safety class: All OTDR laser

sources specified by this data sheet
are classified as Class 1M according
to IEC 60825–1 (2001).

The Visual Fault Finder Sub-Module
E6007A complies with Class 2 according to
IEC 60825–1 (2001).

All laser sources comply with 21 CFR
1040.10 except for deviations pursuant to
Laser Notice No. 50, dated 2001-July-26

Recommended module recalibration

period: 2 years. (OTDR Modules and
Power Meter only)

Dimensions: 194 mm H, 290 mm W,

75 mm D (7.7” x 11.4” x 3.0”).

Weight: net < 2.9 kg (6.4 lbs), typical,

including battery pack and OTDR
module.