Atec Agilent-8156A User Manual
Page 4

Page 4 of 8
Variable Optical Attenuator Modules (Single Mode Fibers)
81570A 81571A
Connectivity
straight connector
versatile interface
angled connector
versatile interface
Fiber type
9/125
µm SMF28
Wavelength range
1200 nm – 1700 nm
Attenuation range
0 – 60 dB
Resolution 0.001
dB
Repeatability
[1]
± 0.01 dB
Accuracy (uncertainty)
[1], [2], [3], [4]
± 0.1 dB (at 1550 nm)
typ.
± 0.1 dB (1250 nm – 1650nm)
Settling time
[5]
typ. 100 ms
Transition speed
typ. 0.1 – 12 dB/s
Attenuation flatness
[1], [4], [6], [8]
± 0.07 dB; typ. ± 0.05 dB (1520 nm < λ < 1620 nm)
typ.
± 0.10 dB (1450 nm < λ < 1640 nm)
Spectral ripple
[7]
typ.
± 0.003 dB
Insertion loss
[2], [4], [9], [10]
typ. 0.7 dB (excluding connectors)
1.6 dB; typ. 1.0 dB (including connectors)
[11]
Insertion loss flatness
[1], [11]
typ.
± 0.1 dB (1420 nm < λ <1615 nm)
[4]
Polarization dependent loss
[2], [11]
0.08 dBpp; typ. 0.03 dBpp (at 1550nm
± 15nm)
Return loss
[11]
typ. 45 dB
(at 1550nm
± 15nm)
typ. 57 dB
(at 1550nm
± 15nm)
Maximum input power
[12]
+33
dBm
Shutter isolation
typ. 100 dB
Dimensions (H x W x D)
75 mm x 32 mm x 335 mm (2.8” x 1.3” x 13.2”)
Weight 0.9
kg
Recommended recalibration
period
2 years
Operating temperature
10°C – 45°C
Humidity Non-condensing
Warm-up time
30 minutes
[1]
At constant operating conditions
[2]
Temperature within 23°C
± 5°C
[3]
Input Power < +30 dBm
[4]
For unpolarized light
[5]
Step size < 1 dB, for full range: typ. 6 seconds
[6]
Relative to reference at 0 dB attenuation
[7]
Linewidth of source
≥ 100 MHz
[8]
λ
disp
set to 1550 nm; attenuation
≤ 20 dB;
for attenuation > 20 dB:
add typ. 0.01 dB (
α [dB] – 20) for 1520 nm < λ < 1620 nm
add typ. 0.02 dB (
α [dB] – 20) for 1450 nm < λ < 1640 nm
[9]
For
λ = 1550 nm ± 15 nm
[10]
Add typ. 0.1 dB for
λ = 1310 nm ± 15 nm
[11]
Measured with Agilent reference connectors
[12]
Agilent Technologies Deutschland GmbH assumes no responsibility for damages caused by scratched or poorly cleaned connectors.