9 optional form c alarm panel installation – Alpha Technologies FlexNet PMR, GMR Series User Manual
Page 47

031-239-C0-003 Rev C
47
4.0
Equipping the System, continued
4.9 Optional Form C Alarm Panel Installation
The PMR and GMR Series enclosures can be modifi ed to supply Form C alarm signals. The
optional Form C Alarm Panel installs easily into the equipment mounting rack and plugs into
the ELPM 300W power supply, using supplied wiring kits. See Section 2.1 and 2.2 for part
numbers and specifi cations and the ELPM 300 manual for specifi c information on the power
supply.
Fig. 4-24, Form C Alarm Signal Panel
1
2
3
4
5
1
2
3
4
5
Plug into the AC Power outlet at the rear of the enclosure
Plug into the Status Monitoring connector on the ELPM front panel
Plug into the Output connector on the ELPM front panel
Provides connection for customer-supplied monitoring equipment.
Provides for customer-supplied alarm monitoring with the addition of
a "Rectifi er Fail" alarm.
19.00
18.12
1.98
1.00
Fig. 4-25, Form C Alarm Signal Panel Dimensions
- AlphaCell GelCell Series (32 pages)
- FXM 650, 1100, 2000 UPS (96 pages)
- Cordex 48-1.2kW (68 pages)
- Radium MiniBay (57 pages)
- Fiber Backhaul Enclosure (FBE) (19 pages)
- FBE2322 Enclosure System (38 pages)
- Te25xh (38 pages)
- FlexNet MPS48-12M - Technical Manual (33 pages)
- FlexNet MPS48-12M - Quick Start Guide (2 pages)
- FlexNet ELPM 300-48D (25 pages)
- FlexNet FMPS (40 pages)
- FlexPoint AX Series (34 pages)
- FlexPoint FPR1207-F - Technical Manual (18 pages)
- FlexPoint FPR1207-F - Quick Start Guide (2 pages)
- AlphaGen PN-6x-T 7.5kW 48VDC - Installation and Operation Manual (79 pages)
- AlphaGen CE-3x2 5K-T 48Vdc (95 pages)
- AlphaGen PN-6x-T 7.5kW 48Vdc (95 pages)
- AlphaGen 3.5_5.0kW Kohler COM5 (80 pages)
- Security Bar Field For UPE-3, UPE-6, UPE-M3, UPE-M6, PN Series and CE Series (2 pages)
- AMPS80 HP (116 pages)
- 255A Bypass Switch (24 pages)
- AMP24 HP (108 pages)
- FXM350_Micro350 UPS (112 pages)
- CFR 600, CFR 600XT, CFR 1000 (70 pages)
- BPS Series Bypass Switch (36 pages)
- CFR Intelligent Interface Device (54 pages)
- CFR Redundant Control Unit (23 pages)
- CFR 5000, CFR 5000RM (88 pages)
- CFR 3000, CFR 3000RM (86 pages)
- CFR 1500, CFR 1500RM (83 pages)
- CFR 1500, CFR 2000, CFR 2500, CFR 3000 (76 pages)
- Continuity: 1000_2000_3000 (48 pages)
- Continuity Battery Pack (20 pages)
- Continuity: 6K_10K (52 pages)
- Micro, Micro XL, Micro XL3 UPS (99 pages)
- Micro Secure UPS (80 pages)
- Te17 (32 pages)
- Te45 (68 pages)
- Te41, 48V (76 pages)
- Te41, 24V (72 pages)
- Te43 (60 pages)
- AlphaGuard AG-CMT Installation (2 pages)
- AlphaGuard AG-CMT-3SC_4SC-P (2 pages)
- Digital Midtron DM-3200 AT (2 pages)