beautypg.com

Cla-val, Ii 3 g – Cla-Val X144D-AF-X User Manual

Page 4

background image

Insertion Tool and Locking Ring

• Required for removal and reinsertion
• Tool allows the proper installation and alignment

of the bluff body to be parallel to upstream flow.

Cabling

• The unit is supplied with 30 feet of cable.

Approvals

PO Box 1325 Newport Beach CA 92659-0325

Phone: 949-722-4800

Fax: 949-548-5441

CLA-VAL

©

COPYRIGHT CLA-VAL 2012 Printed in USA • Specifications subject to change without notice.

www.cla-val.com

E-X144D-AF-X ( 09/2012)

Represented By:

X144D-AF-X e-FlowMeter Analog Range (4-20mA Scaling): Factory Settings

X144D-AF-X Insertion Tool

Port Style

Line Size

inches (mm)

2"

(50)

(100-49

Body)

2-1/2"

(65)

3"

(80)

4"

(100)

6"

(150)

8"

(200)

10"

(250)

12"

(300)

Full Port Valves

4mA = 0

(GPM - l/s)

20mA Range (GPM)

260

375

575

1000

2250

3900

6000

8750

20mA Range (l/s)

16.4

23.7

36.3

63.1

140

245

380

550

Full Port

Pulse Weight

= 250ms

Gal/Pulse

5

6.5

9.5

17

38

65

100

150

l/Pulse

19

25

36

65

145

245

380

565

Reduced Port

Valves

4mA = 0

(GPM- l/s)

20mA Range (GPM)

not available

675

1600

2900

4500

5650

20mA Range (l/s)

42.5

100

180

285

355

Reduced Port

Valves

Pulse Weight =

250ms

Gal/Pulse

11.5

26

48

75

95

l/Pulse

44

99

180

285

360

Note: pulse length = 250ms

Rating:

II 3 G

Ex [d] ia

II

A T5

Self-certification by Cla-Val Co.
1701 Placentia Avenue
Costa Mesa, CA 92627,
per Annex VIII, Internal Control
Production per Annex VIII

Mfd. by Cla-Val Co.

1701 Placentia Avenue

Costa Mesa, CA 92627 USA

www.cla-val.com • 800.942.6326

Model #: X144D-AF-X

Serial #:

EX [d] ia

II

A T5

Max. Voltage : 30 VDC
Max. Power : 750mW
Signal Output : 4-20mA
Max. Temp. : 100° C

Electrical Data & Product Labeling