Cla-val, Ggg d, Dd f – Cla-Val 100-04 User Manual
Page 5: Ae c, Kj h, Aa b, Flanged

CLA-VAL
Copyright Cla-Val 2011 Printed in USA Specifications subject to change without notice.
P.O. Box 1325
• Newport Beach, CA 92659-0325 • Phone: 949-722-4800 • Fax: 949-548-5441 • E-mail: [email protected] • Website cla-val.com
©
Dimensions
Model 100-04
Service
Cla-Val Control Valves operate with maximum efficiency when mounted in horizontal piping with the main valve cover UP, however, other
positions are acceptable. Due to component size and weight of 8 inch and larger valves, installation with cover UP is advisable. We recommend
isolation valves be installed on inlet and outlet for maintenance. Adequate space above and around the valve for service personnel should be
considered essential. A regular maintenance program should be established based on the specific application data. However, we recommend a
thorough inspection be done at least once a year. Consult factory for specific recommendations.
E-100-04 (R-8/2011)
Valve Size
(Inches)
2
3
4
6
8
10
12
14
16
A 150 ANSI
9.38
12.00
15.00
20.00
25.38
29.75
34.00
39.00
41.38
AA 300 ANSI
10.00
13.25
15.62
21.00
26.38
31.12
35.50
40.50
43.50
B Dia.
6.62
9.12
11.50
15.75
20.00
23.62
28.00
32.75
35.50
C Max.
6.50
8.19
10.62
13.38
16.00
17.12
20.88
24.19
25.00
D 150 ANSI
4.75
6.00
7.50
10.00
12.69
14.88
17.00
19.50
20.69
DD 300 ANSI
5.00
6.38
7.81
10.50
13.19
15.56
17.75
20.25
21.75
E
1.50
2.56
3.19
4.31
5.31
9.25
10.75
12.62
15.50
F 150 ANSI
2.50
3.75
4.50
5.50
6.75
8.00
9.50
10.50
11.75
FF 300 ANSI
3.25
4.13
5.00
6.25
7.50
8.75
10.25
11.50
12.75
G 150 ANSI
3.25
4.00
5.00
6.00
8.00
8.62
13.75
14.88
15.69
GG 300 ANSI
3.25
4.38
5.31
6.50
8.50
9.31
14.50
15.62
16.50
H NPT Body Tapping
.375
.50
.75
.75
1
1
1
1
1
J NPT Cover Center Plug
.50
.50
.75
.75
1
1
1.25
1.50
2
K NPT Cover Tapping
.375
.50
.75
.75
1
1
1
1
1
Valve Stem Internal
Thread UNF
10-32
1
⁄
4
-28
1
⁄
4
-28
3
⁄
8
-24
3
⁄
8
-24
3
⁄
8
-24
3
⁄
8
-24
3
⁄
8
-24
1
⁄
2
-20
Stem Travel
0.6
0.8
1.1
1.7
2.3
2.8
3.4
4.0
4.5
Approx. Ship Wt. Lbs.
35
70
140
285
500
780
1165
1500
2265
Valve Size
(mm)
50
80
100
150
200
250
300
350
400
A 150 ANSI
238
305
381
508
645
756
864
991
1051
AA 300 ANSI
254
337
397
533
670
790
902
1029
1105
B Dia.
168
232
292
400
508
600
711
832
902
C Max.
165
208
270
340
406
435
530
614
635
D 150 ANSI
121
152
191
254
322
378
432
495
526
DD 300 ANSI
127
162
200
267
335
395
451
514
552
E
38
65
81
109
135
235
273
321
394
F 150 ANSI
76
95
114
140
171
203
241
267
298
FF 300 ANSI
83
105
127
159
191
222
260
292
324
G 150 ANSI
83
102
127
152
203
219
349
378
399
GG 300 ANSI
89
111
135
165
216
236
368
397
419
H NPT Body Tapping
.375
.50
.75
.75
1
1
1
1
1
J NPT Cover Center Plug
.50
.50
.75
.75
1
1
1.25
1.50
2
K NPT Cover Tapping
.375
.50
.75
.75
1
1
1
1
1
Valve Stem Internal
Thread UNF
10-32
1
⁄
4
-28
1
⁄
4
-28
3
⁄
8
-24
3
⁄
8
-24
3
⁄
8
-24
3
⁄
8
-24
3
⁄
8
-24
1
⁄
2
-20
Stem Travel
15
20
28
43
58
71
86
102
114
Approx. Ship Wt. Kgs.
16
32
64
129
227
354
528
726
1027
G
GG
D
Inlet
DD
F
100-04
Flanged
A
E
C
(MAX)
K
J
H
Inlet
Outlet
AA
B
(Diameter)