Remote contr ol, cont’d – Extron Electronics VSC 75 User Guide User Manual
Page 14
VSC 75 Serial Communication
VSC 75 Serial Communication
Remote Contr
ol, cont’d
Freeze
Set Freeze mode to On (freeze the displayed image)
F
46
Frz 1
Enable freeze
Set Freeze mode to Off (release the displayed image)
f
66
Frz 0
Disable freeze
Executive mode
Set Executive mode to On
X
58
Exe 1
Enable executive
Set Executive mode to Off
x
78
Exe 0
Disable executive
Test mode
Set Test mode to On
J
4A
Dmo 1
Enable test
Set Test mode to Off
j
6A
Dmo 0
Disable test
Firmware version, part number & information requests, and reset
System reset
Esc z
1B 7A 0D
Zap
Reset to factory default
Query firmware version number
Q/q
51/71
Ver x.xx
Display firmware version
Request part number
N/n
4E/6E
N60-321-01
Display VSC 75’s part #
Request information
Command =
I/i
49/69
(see below)
Display status
Response =
Dvt
X1
• Frz
X2
• Exe
X2
• Dmo
X2
Command/response table
Command description
Command
Response
Additional
ASCII
Hex
to host
description
Horizontal shift
Shift right one step
{ H
7B + 48
Hph +
Increment up
Shift left one step
} H
7D + 48
Hph -
Increment down
Vertical shift
Shift down one step
{ /
7B + 2F
Vph +
Increment up
Shift up one step
} /
7D + 2F
Vph -
Increment down
Horizontal size
Increase horizontal size by one step
{ :
7B + 3A
Hsz +
Increment up
Decrease horizontal size by one step
} :
7D + 3A
Hsz -
Increment down
Vertical size
Increase vertical size by one step
{ ;
7B + 3B
Vsz +
Increment up
Decrease vertical size by one step
} ;
7D + 3B
Vsz -
Increment down
Flicker/vertical filter (detail)
Select flicker/vertical filter
X1
(Dvt)
X1
d
X1
+ 64
X1
Dvt
Specific value
Select next higher flicker/vertical filter (Dhz + 1)
{ d
7B + 64
Dvt
X1
Increment up
Select next lower flicker/vertical filter (Dhz - 1)
} d
7D + 64
Dvt
X1
Increment down
3-5
3-4
Symbol definitions
= CR/LF (carriage return/line feed)
= CR (carriage return only)
• =
Space
X1
= Vertical filtering
level (1 through 2)
X2