Board Setup and Operation

On the MTP T 15HD RSA board there are two DIP switches (switch #1 is for refresh rate, switch #2 is for audio/RS-232), and a
16-position rotary encoder for EDID selection.
The default settings are: DIP switch #1 60 Hz (down), DIP switch #2 audio (down), EDID encoder 1024x768 (position 2).
On the MTP R 15HD RSA SEQ board there are four active DIP switches. They are: switch #1 = Horizontal sync, switch #2 =
Vertical sync, switch 3 = RS-232 communication, switch #4 = Chroma routing, Switches 5 and 6 are not used.
The default settings are: DIP switch #1 H– (down), DIP switch #2 V– (down), DIP switch #3 unidirectional RS-232 (down),
DIP switch #4 is MTP S-video (down), DIP switch #5 and #6 not used (down)
Access to the DIP switches and encoder is via a cut-out in the cover. Either change the settings before installation, or remove
the board from enclosure to access the switches. See below for all DIP switch and EDID settings.

Changing the MPT T 15HD RSA Board Settings

1.

Flip the DIP switches to the setting required.

Switch Position

Switch #1 Setting

Switch #2 Setting

Up/On

50 Hz

RS-232

Down/Off (default) 60 Hz

Audio

2.

Using a small screwdriver, rotate the encoder pointer to the number or letter corresponding to the resolution required.
See below for EDID encoder positions and resolutions:

Position

Resolution

Position

Resolution

0

N/A

8

1366 x 768

1

800 x 600

9

1400 x 1050

2

1024 x 768 (default)

A

1440 x 900

3

1280 x720

B

1600 x 1200

4

1280 x 768

C

1680 x 1050

5

1280 x 800

D

1920 x 1080

6

1280 x 1024

E

1920 x 1200

7

1360 x 768

F

N/A

Changing the MPT R 15HD RSA SEQ Board Settings

Change any of the four active DIP switches to the settings as shown in the table below.

Switch

Position

Switch #1

Setting

Switch #2

Setting

Switch #3

Setting

Switch #4

Setting

Switch #5

Setting

Switch #6

Setting

Up/On

H+

V+

Bidirectional

S-Video

green (luma)
blue (chroma)

N/A

N/A

Down/Off

(default)

H-

V-

Unidirectional MTP standard

green (luma)
red (chroma)

N/A

N/A

Skew, Level, and Peaking Adjustments

On the rear panel of the MTP R 15HD RAS SEQ board are
three colored LEDs, a recessed select button, and an Adjust
knob. These work in conjunction to allow the user to make
adjustments to image skew delay, level, and peaking.
Referring to the table at right, press the select button as
desired. Rotate the Adjust knob to adjust the selected
function while monitoring the displayed image.
Refer to the Powercage MTP 15HD RSA Series User Guide for details about

skew delay, level, and peaking.

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

68-1644-50

Rev A

08 10

O

N

1 2

ON

1 2 3 4 5 6

1 = H SYNC

2 = V SYNC

3 = RS-232

4 = S-Video/MTP

5 = Not Used

6 = Not Used

Button presses

Function

LED Color

1

Red skew delay

Red

2

Green skew delay

Green

3

Blue skew delay

Blue

4

Level

Green (Blinking)

5

Peaking

Blue (Blinking)

©2010 Extron Electronics. All Rights Reserved -