beautypg.com

Connections, Mda 4v hd-sdi and sdi user's guide – Extron Electronics MDA 4V SDI User Guide User Manual

Page 8

background image

MDA 4V HD-SDI and SDI User's Guide • Introduction

MDA 4V HD-SDI and SDI User's Guide

MDA 4V HD-SDI and SDI User's Guide • Introduction

MDA 4V HD-SDI and SDI User's Guide • Connections

MDA 4V HD-SDI and SDI User's Guide • Connections

Connections

MDA 4V SDI

POWER
12V

.5A MAX

1

2

3

4

SDI INPUT

SDI OUTPUTS

POWER

12V

0.4A MAX

OUTPUTS

1

2

3

4

MDA 4V HD-SDI

INPUT

1

3

2

1

3

2

Figure 8 — MDA 4V HD-SDI and SDI rear panels

a

HD-SDI or SDI Input connector

— Connect an HD-SDI or SDI

input to this BNC connector. The MDA automatically equalizes

input, regardless of the rate.

N

The MDA 4V HD-SDI can handle SDI video at the

signal rate of 270 Mbps.

b

HD-SDI or SDI Outputs (1 through 4) connectors — Connect

up to four HD-SDI or SDI devices to these BNC connectors. If

the MDA recognizes the input rate, the MDA outputs re-clocked

HD-SDI or SDI outputs.

c

Power connector — Plug the external 12 VDC power supply

into this 2-pole captive screw connector. The power supply is

included with the unit. Figure 9, on the next page, shows how

to wire the connector.

C

Voltage polarity is critical when you are connecting

the power supply. Applying power with incorrect

voltage polarity could damage the power supply and

the MDA. Identify the power cord negative lead by

the ridges on the side of the cord.

Power Supply

Output

Cord

Captive Screw

Connector

SECTION A–A

Ridges

Smooth

A

A

Tie Wrap

Figure 9 — Power connector wiring

To verify the polarity before connection, plug in the power

supply with no load and check the output with a voltmeter.

W

The two power cord wires must be kept separate

while the power supply is plugged in. Remove

power before wiring.

C

The length of the exposed (stripped) copper wires

is important. The ideal length is 5/16" (7 mm).

Longer bare wires can short together. Shorter wires

are not as secure in the connectors and could be

pulled out.

Use the supplied tie-wrap to strap the power cord to the

extended tail of the connector.

N

Your MDA may have shipped with a blue captive screw

connector. This blue connector can be plugged into

either a blue or an orange power receptacle.

The blue connector does not have the extended tail or the

included tie-wrap.

N

Do not tin the power supply leads before installing them

in the direct insertion connector. Tinned wires are not as

secure in the connectors and could be pulled out.

Alternatively, an Extron P/S 123 Universal 12 VDC Power

Supply, part #60-814-01, can power up to eight MDAs or other

Extron 12 VDC devices using only one AC power connector.