Installation and Operation, cont’d

VersaTools

®

MDA EQ Series • Installation and Operation

VersaTools

®

MDA EQ Series • Installation and Operation

9

.

Move the PMK 350 up to the desired location on the
ceiling pole, as close to the ceiling as desired.

10

.

Secure the L bracket to the U-bolt, using the included hex
nuts. Hand-tighten the hex nuts, make any final
adjustments to the PMK’s position, then tighten the hex
nuts securely, using an 11/16" deep socket or box-end
ratchet wrench.

N

Be sure to tighten the hex nuts securely enough that the
PMK 350 does not slide down the ceiling pole.

11

.

Secure the front panel to the mounting tray with four of
the included #6 screws.

12

.

If desired, tear out one of the four perforated self-adhesive
overlay sheets, and apply it to the underside of the
mounting tray.

Rear Panel Features and Cabling

The following figures show the back panel configurations of the
three MDA EQ models.

MDA 2V EQ

POWER

12V
0.2A MAX

INPUT

OUTPUTS

HIGH Z

IN

1

2

75 Ohm

INPUT

LOOP-THRU

LOOP-THRU

1

2

3

6

4

MDA 2V EQ rear panel

MDA 4V EQ

POWER

12V
0.2A MAX

INPUT

INPUT

LOOP-THRU

OUTPUTS

HIGH Z

IN

1

2

75 Ohm

3

4

6

4

1

2

3

MDA 4V EQ rear panel

INPUT

MDA 4SV EQ

POWER

12V
0.2A MAX

INPUT

LOOP-THRU

OUTPUTS

HIGH Z

IN

2

75 Ohm

4

1

3

1

2

3

5

7

MDA 4SV EQ rear panel

1

Power connector —

Plug the external 12 VDC power supply

into this 2-pin, 3.5 mm captive screw connector. The power
supply is included with the unit.

The power connector on the rear panel is orange;
however, the plug for the power cord may be either
orange or blue. Either color plug can be connected to the
rear panel receptacle.

To wire the connector:

1

.

Cut the DC output cord to the length needed.

2

.

Strip the jacket to expose 0.2" (5 mm) of the conductors for
the blue captive screw plug, or 0.3" (7 mm) for the orange
plug.

W

Exposing more than the amount of copper wire
described above could allow the stripped wires to
touch each other, causing a short circuit. This
could result in the external DC power supply
overheating and/or burning.

N

Stripping the wires to expose less than the recommended
amount causes them to slide out of the connector too
easily, even if they are tightly pinched by the captive
screws.

3

.

Slide the leads into the supplied captive screw plug and
lock them, using an Extron Tweeker (small screwdriver).

4

.

Use the supplied tie-wrap to strap the power cord to the
extended tail of the connector.

5

.

To verify the power cord’s polarity before connecting it,
plug in the power supply with no load and check the
output with a voltmeter.

2-10