beautypg.com

Cd e – Extron Electronics Flexible Conduit Adapter Kit User Manual

Page 4

background image

Flexible Conduit Adapter Kit Installation Guide (Continued)

44

3.

Remove the two screws holding the hot (brown) wire and the neutral (blue) wire from the terminal block on the PCB.

100-240V

1.3

A 50-60Hz

Remove screws
(both sides) to release
IEC connector plate.

Remove nut from grounding stud.

Blue Wire

Brown Wire

L

N

Remove two screws from
terminal block.

c

d

e

Figure 6.

Removing the Wires and the IEC Connector Plate

4.

Remove the ground wire nut from the grounding stud on the bottom of the enclosure, as shown in figure 6, above.

5.

Remove the two screws from the IEC plate and remove the IEC connector plate and the attached wires through the rear
panel of the XPA.

6.

Thread the 12- or 14-gauge power wires through the length of the electrical conduit tube.

7.

Install the EMT adapter plate with conduit attached into the opening from which the IEC connector was removed in
step 5.

8.

Slide the conduit nut over the bundle of wires that are exiting the conduit, and onto the conduit itself (see figure 7).
Hand tighten the conduit nut to the conduit.

WARNING:

Ensure that you observe correct wire polarity. The illustration above shows the location of the hot (L)
and neutral (N) terminals.

LINE

NEUTRAL

L

N

Conduit Nut

EMT Adapter Plate

Terminal Block

Zip-Tie

Ground
Wire Nut

Hot
Terminal (Black)
Neutral
Terminal (White)

Figure 7.

Attaching the EMT Adapter Plate Assembly

9.

Attach the EMT adapter plate assembly to the XPA, using the two screws removed in step 5.

10.

Connect the black hot (line) and white neutral wires to the terminal block on the PCB using the two screws that were
removed in step 3. Use the included zip tie wrap to secure the two wires together close to the terminals (see figure 7).

11.

Connect the ground wire to the grounding stud on the bottom of the enclosure using the nut that was removed in
step 4 (see figure 7, above).

12.

Replace the cover of the XPA by attaching the eight screws that were removed in step 2.

Extron USA - West
Headquarters

+800.633.9876

Inside USA/Canada Only

+1.714.491.1500
+1.714.491.1517
FAX

Extron USA - East

+800.633.9876

Inside USA/Canada Only

+1.919.863.1794
+1.919.863.1797
FAX

Extron Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040
+31.33.453.4050
FAX

Extron Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400
+65.6383.4664
FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656
FAX

Extron China

+400.833.1568

Inside China Only

+86.21.3760.1568
+86.21.3760.1566
FAX

Extron Middle East

+971.4.2991800
+971.4.2991880
FAX

© 2010 Extron Electronics All Rights Reserved.