beautypg.com

Using the pre-programmed extron edid – Extron Electronics EDID 101D_101V User Guide User Manual

Page 15

background image

EDID 101D/EDID 101V • Installation and Operation

11

Using the pre-programmed Extron EDID

N

Configuring the EDID 101 rotary and DIP switches allow

a user to select a pre-programmed EDID based on the native

rate of a display (i.e. 1280x1024 @ 60 Hz) and a desired

signal type (i.e. digital), but does not necessarily force a video

source to output that rate.

Since EDID is not limited to reporting a single video rate

(i.e. the native rate), each Extron EDID also lists other

common video rates for use by the video source.

Choose a resolution from Table 1 based on the native resolution

1.

of the display. Note the corresponding rotary switch position.
To use the EDID, set the rotary switch (

2.

d

) to the

position (1-F) selected in step 1. The switch clicks as

it moves through the positions.

Rotary Switch

Position

Resolution

0

User Recorded EDID

1

800x600

2

1024x768

3

1280x720

4

1280x768

5

1280x800

6

1280x1024

7

1360x768

8

1366x768

9

1400x1050

A

1440x900

B

1600x1200

C

1680x1050

D

1920x1080

E

1920x1200

F

Digital:

Dual Link DVI

Analog:

Not Used

Table 1 — Rotary Switch position

N

When using a dual link DVI display with the EDID 101D

(position F), only two resolutions will be shown to the video

source, 1280x800 and 2560x1600.

Set the first DIP switch (

3.

c

) based on the

vertical refresh of the native rate of the display.

(default is ON, 60 Hz).
For the EDID 101D only, choose digital or

4.

analog based on the input signal format.
Install the EDID 101 into the system.

5.

4 6

7

8

9

AB

5

3

2

1

0 F

E D C

1 2

ON

60

Hz

50

DIGITAL

SIGNAL

ANALOG