beautypg.com

Edid 101d/edid 101v operation, Recording a display edid, Installation and operation, cont’d – Extron Electronics EDID 101D_101V User Guide User Manual

Page 14

background image

EDID 101D/EDID 101V • Installation and Operation

Installation and Operation, cont’d

10

EDID 101D/EDID 101V Operation

The EDID 101 can either record EDID from a display device or a

pre-programmed EDID can be selected using the rotary and DIP

switches.

Recording a display EDID

To record a new EDID into memory:

Turn the rotary switch (

1.

d

) to position 0.

N

The DIP switch positions have no effect in this mode.

Apply power to the EDID 101 by connecting a power

2.

source.

N

If power is not available from a video source, an external

12 VDC power supply can be used. The green LED will

be lit when power is available.

Connect the display device to the

3.

OutPut

of the

EDID 101 using a DVI (EDID 101D) or a VGA (EDID 101V)

cable.

N

To capture analog EDID on the EDID 101D, a DVI-A to

VGA adapter must be used.

Power on the display device.

4.

N

Although the EDID 101 supplies 5 VDC to power the

EDID circuitry of a display device, power on the display

device to ensure that data is being transmitted during

the recording process.

Press and hold the recessed record button (

5.

b

) until the

LED flashes red rapidly, then release the button. The LED

continues to flash red, then returns to solid green when

the EDID data has been stored. The display can now be

disconnected.

N

If an external supply was used for recording, it can now

be disconnected.

Install the EDID 101 into the system.

6.