beautypg.com

Extron Electronics DMS 1600_2000_3200_3600 Setup Guide User Manual

Page 14

background image

18

DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr

ol

19

DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Contr

ol

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Channel mute commands

Channel mute

X@

*1B

Vmt

X@

*1

]

Mute output

X@

(no signal is output).

Channel unmute

X@

*0B

Vmt

X@

*0

]

Unmute output

X@

(signal is output).

Read channel mute

X@

B

X$]

1 = mute on, 0 = mute off.

Global channel mute

1*B

Vmt1

]

Mute all outputs.

Global channel unmute

0*B

Vmt0

]

Unmute all outputs.

View output mutes

E

VM

}

X$

1

X$

2

...

X$

n

]

Each

X$

response is the mute status of an output,

starting from output 1.
n = the maximum number of outputs for your
configuration.

Save and recall presets

NOTE: If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.

Save current configuration as a
global preset

X%

,

Spr

X%]

Command character is a comma.

Example:

9,

Spr09

]

Save current ties as preset 9.

Recall a global preset

X%

.

Rpr

X%]

Command character is a period.

Example:

5.

Rpr05

]

Recall preset 5, which becomes the current
configuration.

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Information requests

Information request

I

V

X^

X

X&

A0X0

S

X*

1

X*

2

...

X*

n

]

In the response:

V

X^

X

X&

shows the number of available inputs and

outputs for this configuration.

A0X0 has no meaning for this product.

S

X*

1

X*

2

...

X*

n

shows the board type installed in each

slot. n is the highest numbered board in your system,

4, 5, 8, or 9.

Request part number

N

X(]

See the Extron website,

www.extron.com

, for part

numbers.

Request part number and board
configuration

*N

X(

.

X*

1

X*

2

X*

3

...

X*

n

]

n is the highest numbered board in your system, 4, 5,

8, or 9.

Query controller firmware
version

Q

X1)]

Example:

Q

1.23

]

The factory-installed controller firmware version is

1.23 (sample value only).

NOTE:

X@

= Output number

01 – maximum number of outputs for your configuration

X$

= Mute status

0 = not muted, 1 = muted

X%

= Global preset number

01 – 32

NOTE:

X^

= Inputs

Total number of inputs for this switcher

X&

= Outputs

Total number of outputs for this switcher

X*

= Board installed

X0 = No board installed

C1 = 4 DVI inputs by 4 DVI outputs

F1 = 4 fiber inputs x 4 fiber outputs

C2 = 4 DVI inputs by 0 outputs

F2 = 4 fiber inputs x 0 outputs

C3 = 0 inputs by 4 DVI outputs

F3 = 0 inputs x 4 fiber outputs

X(

= Part number

60-nnnn-nn

X1)

= Firmware version number to second decimal place (x.xx)