beautypg.com

Ground loops – Extron Electronics DTP DVI 230 D User Guide User Manual

Page 20

background image

DTP DVI 230 D Transmitter and Receiver • Installation and Operation

14

Ground Loops

When installing the DTP DVI 230 D series products, be sure to avoid scenarios where the
ground potential differs greatly between the locations where the DTP transmitter and DTP
receiver are installed. Such situations can cause ground loops, which can result in image
drops, no image, or damage to the units. If such installations cannot be avoided, it is
necessary to isolate the ground between the DTP transmitter and receiver.

NOTES:

Grounding DTP series units will disable analog audio transmission and the remote
power feature.

Both DTP transmitter and receiver will need to be powered locally.

To eliminate a ground loop:

1.

Remove all screws on the left, right, and top of both the DTP transmitter and receiver
units.

2.

Remove the rear enclosure of each unit.

3.

Locate and remove shunt jumpers at locations labeled JMP2 and JMP3 on both
transmitter and receiver (see figure 13 for jumper locations).

JMP 3
JMP 2
JMP 1

DTP HDMI 230 D Tx

DTP HDMI 230 D Rx

JMP 3

JMP 2

JMP 1

Figure 13.

DTP DVI 230 D Internal Jumper Locations

4.

Replace the rear enclosures and screws.

5.

Install units with an external power supply placed at each end.

6.

Use UTP cable between the DTP transmitter and receiver. If STP cable has already been
installed and terminated, disconnect the shielding at one end to discontinue the ground
path.