CONCENTRIC VENT TERMINATIONS

For new installations, install 2” or 3” ULC S636 certified PVC or

CPVC concentric vent terminations may be used. See the vent

termination manufacturer’s instructions for complete installation

information or contact customer service at 1-888-479-8324

or [email protected]. For planning purposes, see

figures 10-13 below for vent terminal specifications.
Note: For replacement installations, previously installed

American Water Heater Company supplied concentric vent kits

are acceptable for use on 100,000-130,000 BTU/Hr models only.

(14.6cm)

(15.7cm)

(8.9cm Dia.)

(42.2cm)

(84.77cm)

(4.8cm)

(3.8cm)

Figure 10: 2 Inch Concentric Vent

(2.54cm)

Figure 11: Through the Wall Termination

12” (30.5cm) Minimum
clearance above
anticipated snow level.
24” (61cm) Max.

Figure 12: Through the Roof Termination

Notes:
1. Support Horizontal Pipe Every

Four Feet (1.2 m). Support

Vertical Pipe Every Six ft. (1.8 m).

2. Increase The 12 Inch (30.5 cm)

Minimum Above Grade To Keep

Inlet Opening Above Anticipated

Snow Levels.

3. Slope All Piping Down Toward

the Water Heater as follows:

‡ ´3LSLQJVORSH

´3HU)RRWPPSHUPHWHU

‡ ´3LSLQJVORSH

´3HU)RRWPPSHUPHWHU

´FPPD[LPXPZKHQXVLQJ

´SLSH

*

*

*

18”

(45.7cm)

Max.

12” (30.5cm)

Minimum Above

Grade or

Anticipated

Snow Level.

(See Note 2.)

See Note 4

Figure 13: Through the Wall Termination

For clarity, T&P discharge line not shown. See the Temperature

and Pressure Relief Valve section for requirements.

Concentric Venting Multiple Water
Heaters (All Models)

When using two Polaris

®

units, install vent terminations

using either Method E or Method F below:

Note: For installation of more than two Polaris

®

units,

follow the pattern established in Method G.

2” (5.08 cm)

Max.

36” (.9144 m) Min.

2” (5.08 cm)

Max.

36” (.9144 m) Min.

Figure 13E, 13F, 13G