beautypg.com

Warning – John Wood Atmospheric Gas (Standard) User Manual

Page 19

background image

19

WARNING

Explosion Hazard

Replace view port if glass is missing
or damaged.

Failure to do so can result in death,
explosion or fire.

Lighting Instructions

Read and understand these directions thoroughly before

attempting to light or re-light the pilot. Make sure the view

port is not missing or damaged. (See Figure 21.) Make

sure the tank is completely filled with water before lighting

the pilot. Check the rating plate near the gas control valve/

thermostat for the correct type of gas. Do not use this

water heater with any gas other than the one listed on the

rating plate. If you have any questions or doubts, consult

your gas supplier or gas utility company.

OPERATING YOUR WATER HEATER

Lighting the Pilot:
1. Read and follow the lighting instructions on the water

heater’s label.

2. Turn the Control Knob to Pilot. Press the Knob in fully

and hold it in. (The knob will travel in about 1/4-inch

(6.35 mm) if it is set to Pilot correctly.)

3. Click the Igniter button continuously for up to 90

seconds or until the Status Light begins to blink.
If the Status Light does not begin to blink after 90

seconds, STOP. Wait 10 minutes before attempting

to relight the Pilot. Repeat these steps 2-3 times, if

necessary.
The circuitry in this gas valve requires that you wait 10

minutes between lighting attempts.
If the Status Light blinks, release the Control

Knob and turn it to the desired setting. (“Hot” is

approximately 120°F [48.9°C].)

If the Status Light Does Not Blink:
1. Wait 10 minutes before another lighting attempt.
2. If the Status Light did not blink, repeat the lighting

procedure by following the lighting instructions on

the water heater’s label. Remove the outer door.

The Control Knob must be set to Pilot and held in

continuously while clicking the igniter button (about

once per second for up to 90 seconds). To observe the

Pilot, remove the outer door and look through the view

port (sight glass). See Figure 21.

3. Continue clicking the Igniter button (for up to 90

seconds) until Pilot lights.

4. Once the Pilot is lit, continue to hold the Control Knob

in until the Status Light begins to blink.

5. Release Control Knob and set Knob to desired

temperature setting. (“Hot” is approximately 120°F

[48.9°C].)

6. Replace the outer door.

If the Pilot Does Not Light:
1. Wait 10 minutes before another lighting attempt.

If the pilot does not light, the Igniter may not be

sparking or the unit may not be getting gas (or for a

new installation, there may still be air in the gas line).
Each time you click the igniter button, you should be

able to see the spark by looking through the view port.

See Figure 21. (You may have to darken the room

lights to see the spark.) You do not have to push the

Control Knob in to check the Igniter button. Simply

look through the sight glass while clicking the Igniter

button and look for a spark. If you can’t see a spark

when the Igniter button is clicked, check the wiring

connections from the Igniter button and make sure that

they are tight.

2. If you see the Igniter spark, try relighting the pilot by

following the instructions on the water heater’s label.

Ensure that the gas supply is tuned on. There may

be air in the gas line, and several lighting attempts

may be needed to completely fill the line with gas and

successfully light the pilot.

If the Pilot Lights but the Status Light Does Not Blink:
1. If the pilot lights, continue to hold the Control Knob

in until the Status Light blinks. If the pilot is lit and

remains lit for 90 seconds and the Status Light still

does not blink, the thermopile connections may be

loose, the thermal switch may need to be reset, or the

thermopile may be defective.

2. Remove the outer door.
3. Press the reset button on the thermal switch (Figure 21).
4. If switch clicks, it may have tripped. Do not light the

Pilot if flammable vapors are present. Check flame

arrestor for signs of discoloration (which could be

caused by flammable vapors). If the flame arrestor is

discolored, do not attempt to relight the Pilot. Have

the water heater inspected by a qualified service

technician.

5. Check the wiring connections from the thermopile and

the thermal switch to the gas control valve/thermostat.

Ensure that all wiring connections are tight. See

Figure 21.

6. Replace the outer door.
7. Wait 10 minutes and try to light the Pilot according to

the instructions on the water heater’s label.

8. While clicking the Igniter button continuously,

the Control Knob must be set to Pilot and held

in until the Status Light blinks. Once the Status

Light blinks, release the Control Knob and set the

Knob to the desired temperature setting. (“Hot” is

approximately 120°F [48.9°C].)