16

METAL
DRAIN PAN

DRAIN

DRAIN LINE 3/4”

ID MINIMUM

DISCHARGE PIPE

DO NOT CAP OR PLUG

TEMPERATURE AND PRESSURE RELIEF (T&P)
VALVE (OPTIONAL TOP T&P RELIEF
VALVE NOT SHOWN)

1” (2.54 cm)

MINIMUM

12” (300 mm)

MAXIMUM AIR GAP

FIGURE 13A.

For protection against excessive pressures and

temperatures, a temperature and pressure relief valve must

be installed in the opening marked “T & P RELIEF VALVE”

(see Figure 13A). This valve must be design certified by

a nationally recognized testing laboratory that maintains

periodic inspection of the production of listed equipment or

materials as meeting the requirements for Relief Valves for

Hot Water Supply Systems, ANSI Z21.22/CSA 4.4-current

edition. The function of the temperature and pressure relief

valve is to discharge water in large quantities in the event

of excessive temperature or pressure developing in the

water heater. The valve’s relief pressure must not exceed

the working pressure of the water heater as stated on the
rating plate.
IMPORTANT: Only a new temperature and pressure relief

valve should be used with your water heater. Do not use an

old or existing valve as it may be damaged or not adequate

for the working pressure of the new water heater. Do not

place any valve between the relief valve and the tank.
The Temperature & Pressure Relief Valve:

Must not be in contact with any electrical part.

Must be connected to an adequate discharge line.

Must not be rated higher than the working pressure

shown on the rating plate of the water heater.

The Discharge Line:

Must not be smaller than the pipe size of the relief

valve or have any reducing coupling installed in the

discharge line.

Must not be capped, blocked, plugged or contain

any valve between the relief valve and the end of the

discharge line.

Must terminate a maximum of twelve inches (300 mm)

above a floor drain or external to the building. In cold

climates, it is recommended that the discharge pipe be

terminated at an adequate drain inside the building.

Must be capable of withstanding 250°F (121°C) without

distortion.

Must be installed to allow complete drainage of both

the valve and discharge line.

T&P Relief Valve and Pipe Insulation (Some Models)

1. Locate the temperature and pressure relief valve on

the water heater (also known as a T&P relief valve).

See Figure 13B.

2. Locate the slit running the length of the T&P relief

valve insulation.

3. Spread the slit open and fit the insulation over the T&P

relief valve. See Figure 13B. Apply gentle pressure

It is recommend that only full flow ball or gate valves

are used in water piping installations. The use of valves

that may cause excessive restriction to water flow is not

recommended.

Use only 95/5 tin-antimony or other equivalent solder.

Any lead based solder must not be used.

Piping that has been treated with chromates, boiler seal,

or other chemicals must not be used.

Chemicals that may contaminate the potable water

supply must not be added to the piping system.

Closed System/Thermal Expansion

As water is heated, it expands (thermal expansion). In a

closed system, the volume of water will increase. As the

volume of water increases, there will be a corresponding

increase in water pressure due to thermal expansion.

Thermal expansion can cause premature tank failure

(leakage). This type of failure is not covered under the

limited warranty. Thermal expansion can also cause

intermittent temperature-pressure relief valve operation:

water discharged from the valve due to excessive pressure

build up. The temperature-pressure relief valve is not

intended for the constant relief of thermal expansion. This

condition is not covered under the limited warranty.
A properly-sized thermal expansion tank should be

installed on all closed systems to control the effects of

thermal expansion. Contact a plumbing service agency or

your retail supplier regarding the installation of a thermal

expansion tank.

Temperature and Pressure Relief Valve

Explosion Harzard

‡ 7HPSHUDWXUHSUHVVXUHUHOLHI

YDOYHPXVWFRPSO\ZLWK$16,
=&6$DQG$60(
FRGH

‡ 3URSHUO\VL]HGWHPSHUDWXUH-

SUHVVXUHUHOLHIYDOYHPXVWEH
LQVWDOOHGLQRSHQLQJSURYLGHG

‡ 'RQRWSOXJEORFNRUFDSWKH

GLVFKDUJHOLQH

‡ )DLOXUHWRIROORZWKLVZDUQLQJ

FDQUHVXOWLQH[FHVVLYHWDQN
SUHVVXUHVHULRXVLQMXU\RU
GHDWK