Xylem SDI-12 RADAR User Manual
Page 31

The Send identification Command responds with sensor vendor, model, and version data. any
measurement data in the sensor’s buffer is not disturbed.
Command
response
“ai!”
“allccccccccmmmmmmvvvxx...xx
where:
a
is the sensor address (“0-9”, “a-Z”, “a-z”, “*”, “?”).
i
is an upper-case aSCii character.
ll
is the SDi-12 version compatibility level, e.g. version 1.2 is represented as “12”.
cccccccc
is an 8 character vendor identification to be specified by the vendor and usually
in the form of a company name or its abbreviation.
mmmmmm is a 6 character field specifying the sensor model number.
vvv
is a 3 character field specifying the sensor version number.
SDI-12 Command & Response
29
where:
a
is the sensor address (“0-9”, “a-Z”, “a-z”, “*”, “?”).
V
is an upper-case aSCii character.
ttt
is a three digit integer (000-999) specifying the maximum time, in seconds, the sensor
will take to complete the command and have data available in its buffer.
n
is a single digit integer (0-9) specifying the number of values that will be placed in the
data buffer. if “n” is zero (0), no data will be available using subsequent “D” commands
example of an “aV!” command:
Command
response
Time
Values
Description
"aV!"
“a0013
3
return fixed data and
diagnostic data for testing
purposes.
Subsequent Command
response
"aD0"
a+123.456+78.9+y
Key
Description
Units
+123.456 Fixed test data
+78.9
Fixed test data
y
rom checksum test
0 = Failed, 1 = Passed
Send identification Command