Specifications – Xylem 704 PUMP CONTROLLER User Manual
Page 12

12
Specifications
Ultrasonic Sensor 7005-1013
Measuring range:
0,75-10 m
Frequency:
30 kHz
Beam spread:
3
o
Temperature:
20 - +60
o
C
Dimensions:
Ш 103 Ч 94 mm
Materials:
PP green / POM, black
Cable:
12 m shielded oilresistant PVC, can be extended to 100 m
Protection:
IP 68, withstands immersion, max. 1 bar
Pressure Transmitter 7050 or 7060
Measuring range:
0-10m
Transmitter 7050-1413, absolute pressure
0-3m
Transmitter 7060-1413, gauge pressure
0-10m
Transmitter 7060-1423, gauge pressure
0-30m
Transmitter 7060-1433, gauge pressure
Function:
2 wire, 4-20 mA
Accuracy:
±1%
Temperature:
10 - +60
o
C
Dimensions:
Ш 60 Ч 140mm
Materials:
House: PP Diaphragm: Acid-proof steel, AISI 316 L
Cable:
2 x 0,5mm², length 12 m (with 7060-1433: 35m),
can be extended
Mounting:
On bracket (supplied).
Protection:
IP 68, waterproof, withstands immersion, max. 3 bar
Amplifier 704
Measuring range:
Determined by sensor, scaleable in range -999.99 - +999.99
(m, bar, kPa, cm, mm, l/s, ft or in))
Voltage:
220 - 240/110 - 120/24V AC, consumption approx. 10V A
Temperature:
20 - +60
o
C.
Input signal:
From ultrasonic sensor, pressure transmitter or 4 - 20 mA
Accuracy:
±1%
Outputs:
Analog:
0-20/4-20 mA max. 500W
Digital:
4 relays with voltage free charge-over contact
Inductive load: 250V, 4A ohmic, max. 100V A
Data:
RS232
Indication:
Menus and other text in clear language, measured values in
the range 100m to +300m
Operation:
From keyboard: Menu and function control
Dimensions:
185 x 240 x 115mm (hxwxd)
Materials:
Polystyrol, with clear cover
CE:
EN50081-1, EN50082-1
Protection: