beautypg.com

A-100ne, 3 external input signal connections, Motor leadwires signal input wire color codes – Xylem A-100NE CHEMICAL PUMPS User Manual

Page 6: Paddlewheel sensor signal input wiring, Page 6

background image

A-100NE

Page 6

5.3 External Input Signal Connections

The pump will accept a variety of external control input signals; 4-20 mA ,
0-10 VDC, TTL, CMOS, AC Sine Waves, Contact Closures, Hall Effect,
NPN. The 4-20mA and 0-10 VDC loops must be powered.
All wiring connections are to be made inside of the junction box located on
the side of the pump. Special connectors are not required. A liquid-tite
connector is supplied and should be used for the external signal cable. The
signal input wires are color coded to the type of signal being used.

INPUT

VOLTAGE

115V 60Hz

220V 50Hz

HOT

LEADWIRE

NEUTRAL

LEADWIRE

GROUND

LEADWIRE

230V 60Hz

YELLOW

YELLOW

YELLOW

BLUE

BROWN

RED

GREEN

GREEN

GREEN

MOTOR LEADWIRES

SIGNAL INPUT WIRE COLOR CODES

WIRE COLOR CODE

INPUT TYPE

MOTOR ON SIGNAL

5-20V DC open collector output

closed while motor is energized

FLOW VERIFICATION SENSOR

4-20 mA

0-10 VDC

ALARM RELAY

BROWN (+) & BLACK (-)

PURPLE & PURPLE

WHITE (+) & BLACK (-)

BLUE (+) & BLACK (-)

TTL, CMOS

ORANGE (+) & BLACK (-)

RED/WHITE (+ 20VDC) & BLACK (-) & YELLOW (signal)

CONTACT (10v @ 2 mA max)

HALL EFFECT, NPN

RED (+) & WHITE (-)

PADDLEWHEEL SENSOR SIGNAL INPUT WIRING

PADDLEWHEEL SENSOR

WIRE COLOR CODE

BLUE-WHITE

PADDLEWHEEL

SENSOR TYPE

MODEL FH

HALL EFFECT SENSOR

BLACK (-)

RED (+)

PUMP INPUT

WIRE COLOR CODE

MODEL FC

AC SINE WAVE SENSOR

BARE (signal)

BLACK (-)

RED (+ 20VDC)

WHITE (signal)

BLACK (-)

RED (+)

BLACK (-)

WHITE (+)